background image

15

GUDK-RSO-H053M

GUDK-RSO-H073M

INSTALLATION

STEP 9

INSTALL DRIVE CHAIN

Install the chain ensuring the tension is correct and 

align the 25T sprocket with the drum sprocket.

NOTE: Ensure that all moving parts are adequately 

guarded to prevent injury.

MECHANICAL INSTALLATION COMPLETE

Mechanical install is now complete! The curtain, 

rails and any other items specific to the door can 

now be installed.

Ensure 
alignment

IT IS IMPORTANT TO MAKE SURE THE DOOR ALWAYS RUNS SMOOTHLY. DOORS 

WHICH STICK OR JAM MUST BE REPAIRED IMMEDIATELY. EMPLOY A QUALIFIED 

TECHNICIAN TO REPAIR THE DOOR, NEVER ATTEMPT TO REPAIR IT YOURSELF

  WARNING

Содержание GSB-600

Страница 1: ...berlain New Zealand Ltd PO Box 100 221 North Shore 0745 New Zealand Phone toll free 0800 653 667 THIS OPERATOR IS TO BE INSTALLED AND SERVICED BY A TRAINED TECHNICIAN ONLY Compatible with GLMe2 eDrive 2 0 Wall Control INSTRUCTION MANUAL U Drive Operator for Non Spring Balanced Roller Shutters www grifco com au www grifco co nz ...

Страница 2: ...eight of 1500mm and not accessible to the public Make sure that people who install maintain or operate the door follow these instructions Keep these instructions in a safe place so that you can refer to them quickly when you need to This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless th...

Страница 3: ...ocket 14 Install Drive Chain 15 Electrical Installation 16 17 COMMISSIONING 18 19 Setting Limits 18 Manual Setting of Door Position 19 MAINTENANCE 20 TROUBLESHOOTING 21 22 CHAMBERLAIN LIMITED WARRANTY 24 TABLE OF CONTENTS The U Drive can be operated with a standard GLMe2 Series controller or one of our standard reversing starters The mechanical limit system and high torque output make this an idea...

Страница 4: ...4 TYPICAL INSTALLATION INSTALLATION OF GUDK RSO H073M SHOWN ...

Страница 5: ...MK 05 GUD H073M GUD MK 07 Peak Opener Torque 180 Nm 260 Nm Peak Drum Torque 600 Nm 600 Nm Max Bracket capacity Pair 574 kg 800 Kg Power 0 5 Hp 0 75 Hp Full Load Current 1 8 A 2 A Volts AC 415 V 415V Phase 3 3 Max safety brake speed 16 rpm 16 rpm Output shaft speed 14 rpm 14 rpm Limits 2 x N C Micro Switch 2 x N C Micro Switch Rated Load 110N m RUN TIME 7 6min 183N m RUN TIME 10min Drive Sprocket s...

Страница 6: ... 07 554 104 104 322 130 99 5 180 MIN 180 320 292 MAX 120 10 150 150 150 70 20 180 MIN 90 270 236 MAX 150 150 20 35 80 8 180 MIN 180 320 292 MAX 120 10 150 150 150 70 20 180 MIN 90 270 236 MAX 150 150 20 35 80 8 110 200 250 40 12 43 3 220 46 40 19 112 112 40 12 3 3 40 19 112 112 ...

Страница 7: ...it Not shown F Manual Not shown GUDK RSO H073M COMPLETE CONTENTS GUDK RSO H053M COMPLETE CONTENTS GUD MK 05 A Wall bracket LH B Wall bracket RH C Safety brake angle D Flange bearing E Flange bearing fastener kit Not shown F Safety brake fastener kit Not shown G Wall bracket fastener kit Not shown GSB 600 Safety Brake GSB 600 Safety Brake GUD MK 07 A Wall angle x 2 B Wall bracket x 2 C Safety brake...

Страница 8: ... 42 8 3 47 7 4 54 6 5 4 5m 35 10 0 35 10 0 40 8 8 37 9 5 42 8 3 47 7 4 N A N A N A N A 5m 35 10 0 38 9 2 44 8 0 41 8 5 46 7 6 N A N A N A N A N A N A 5 5m 35 10 0 41 8 5 39 9 0 45 7 8 N A N A N A N A N A N A N A N A 6m 38 9 2 45 7 8 43 8 1 50 7 0 N A N A N A N A N A N A N A N A 6 5m 41 8 5 50 7 0 46 7 6 N A N A N A N A N A N A N A N A N A N A 7m 44 8 0 43 8 1 N A N A N A N A N A N A N A N A N A N ...

Страница 9: ... 8 46 7 6 54 6 5 60 5 8 43 8 1 4 5m 35 10 0 35 10 0 40 8 8 45 7 8 54 6 5 60 5 8 39 9 0 48 7 3 5m 35 10 0 38 9 2 44 8 0 50 7 0 57 6 1 43 8 1 48 7 3 54 6 5 5 5m 35 10 0 41 8 5 48 7 3 57 6 1 42 8 3 47 7 4 54 6 5 60 5 8 6m 38 9 2 45 7 8 54 6 5 60 5 8 45 7 8 54 6 5 60 5 8 N A N A 6 5m 41 8 5 50 7 0 57 6 1 43 8 1 50 7 0 57 6 1 N A N A N A N A 7m 44 8 0 54 6 5 41 8 5 46 7 6 54 6 5 N A N A N A N A N A N A...

Страница 10: ...ake side End Plate must be outside of wall angle as shown below STEP 2 INSTALL DOOR DRUM Install door drum into the bracket slot and position at the correct centre distance from wall U Drive mounting brackets feature positional rebates to allow for easy alignment STEP 3 INSTALL FLANGE BEARING Slide the flange bearing over the end of the shaft and use the M16 fasteners supplied Torque 190Nm 210Nm 1...

Страница 11: ...e using M16 fasteners supplied Torque 190Nm 210Nm STEP 5 INSTALL SAFETY BRAKE 1 Insert 12mm x 8mm x 80mm Key and slide safety brake over shaft 2 Install M10x40 Fasteners and tighten Torque 40Nm 44Nm 3 Install keeper plate using the M10x25 Fastener and tighten Torque 15Nm 17Nm ...

Страница 12: ... ABOVE HORIZONTAL GUD MK 07 ONLY INSTALLATION STEP 6A SELECT MOUNTING CONFIGURATION U Drive s innovative mounting system allows for various operator mounting positions to best suit the application This is enabled by the various mounting configurations and operator mounting position Operator Mounting Plate Positions ...

Страница 13: ...orque 20Nm 22Nm When the gearbox plate is mounted in this orientation the notch must be located closest to motor flange Inside Inside Consideration for access to limit enclosure and motor terminal box required if mounted close to adjacent wall Outside Outside 220 GUD H053M 230 GUD H073M 83 GUD MK 05 120 GUD MK 07 121 GUD H053M GUD H073M 220 GUD H05 230 GUD H07 83 GUD MK 05 120 GUD MK 07 121 GUD H0...

Страница 14: ...interface 2 Use an Eye Bolt and nut not supplied through one of the gearbox mounting holes caution certain positions may cause unbalanced load Fit the gear box bracket using M16 fasteners supplied Torque 190Nm 210Nm STEP 9 INSTALL SPROCKET 1 Install 10mmx8mmx80mm Key and 25T sprocket 2 Grease is recommended between sprocket and shaft 3 Install keeper plate and M10x25 Bolt with spring washer Torque...

Страница 15: ...re adequately guarded to prevent injury MECHANICAL INSTALLATION COMPLETE Mechanical install is now complete The curtain rails and any other items specific to the door can now be installed Ensure alignment IT IS IMPORTANT TO MAKE SURE THE DOOR ALWAYS RUNS SMOOTHLY DOORS WHICH STICK OR JAM MUST BE REPAIRED IMMEDIATELY EMPLOY A QUALIFIED TECHNICIAN TO REPAIR THE DOOR NEVER ATTEMPT TO REPAIR IT YOURSE...

Страница 16: ... country in which it is installed not have control enclosures left open for extended periods excess dust will void warranty MOTOR CONNECTION Connect with min 0 75mm wire using conduit or gland LIMIT CONNECTION Connect with min 0 75mm wire using conduit or gland A DISCONNECTION DEVICE INCORPORATED IN THE FIXED WIRING MUST BE PROVIDED IN ACCORDANCE WITH THE WIRING RULES OF THE COUNTRY IN WHICH IT IS...

Страница 17: ...f an activation of the safety brake the power supply to motor will be cut and no movement will occur until the safety brake is reset or replaced NOTE U Drive is not compatible with the RG378 Series 415V Coils Reversing Starters A DISCONNECTION DEVICE INCORPORATED IN THE FIXED WIRING MUST BE PROVIDED IN ACCORDANCE WITH THE WIRING RULES OF THE COUNTRY IN WHICH IT IS INSTALLED WARNING For complete el...

Страница 18: ...ward travel direction before reaching the closed switch In this case it will stop the motor in either direction This may occur during limit setting and therefore could cause confusion It is important to make sure the door always runs smoothly Doors which stick or jam must be repaired immediately Employ a qualified technician to repair the door never attempt to repair it yourself WARNING The Entrap...

Страница 19: ...to fit into the back of the motor shaft Instructions 1 Insert the tool into the recess on the bottom of the motor 2 Hold the motor brake release lever downward 3 Rotate the tool with suitably powered cordless drill or equivalent The system must be disconnected from the power supply before attempting to operate manually risk of injury if the system is operated electronically whilst the manual opera...

Страница 20: ...ating Use opener less frequently Upgrade to a high cycle opener 14 Direction error Motor connections altered Change door direction and reset limits Constant flash Due for service Door is due for routine service Contact your local door dealer to arrange service No Lights Displayed Power failure No lights on MCB or Controller With lights on at MCB Power supply not correctly connected Bad connection ...

Страница 21: ... come ON when down button is being pressed YES Check for loose motor terminal connection NO Check for control circuit isolating switch or connection between MCB and controller Check for damage to control cable 4 OPENER ACTIVATES FROM CONTROLLER BUT NOT REMOTES Are limits set YES Change remote battery Check key switch if installed position is in Auto or Auto Man and check MCB and Expansion board if...

Страница 22: ...conds After 10 seconds and while still holding CLOSE press and release the SET button Status LED will light up indicating number of cycles performed To read number of cycles follow the Reading Status Flashes routine described below Reading Status Flashes GLMe2 controllers only STATUS indicator will start flashing to signify the value of the least significant digit of the overall number A solidly l...

Страница 23: ...23 ...

Страница 24: ...im is not covered under this Chamberlain Limited Warranty we may subject to your other rights and remedies as a consumer charge you a fee to repair replace and or return the Operator to you This Chamberlain Limited Warranty does not cover any failure of or defect in the Operator due to 1 non compliance with the instructions regarding installation operation maintenance and testing of the Operator o...

Отзывы: