14
INSTALLATION CONTINUED
INSTALLATION MERLIN MJ3800MYQ
Cable entry
Run the cable up along the door track to the rear of the operator, and
through the cable management to the front of the control panel using
appropriate fixings (not supplied). Ensure the cable does not interfere
with the door movement or hardware.
Connection
The photoelectric sensor is supplied prewired to a quick connect plug.
Using a small flat blade screwdriver, loosen the screws on the quick
connect plug, and remove the cables from the plug.
The plug is not needed.
As this product is polarity sensitive, ensure the Brown wire is
terminated into terminal number 5, and the blue wire is terminated into
the terminal number 4.
TO REMOVE AND ERASE MONITORED ENTRAPMENT
PROTECTION DEVICES
Remove the BBU connector and power down the operator. Power the
operator up for three seconds.
Remove power for three seconds.
Repeat three times, leaving power on the third time.
Brown
Blue
WARNING
Only one set of GPS15’s can be installed.
If two sets of safety beams are required, then install GPS772’s or 774ANZ’s