18
Code
Meaning
Solution
Saved
60
Minimum number of Monitored Entrapment Devices
(one) not installed
Review Monitored Entrapment Protection device connections
NO
61
CLOSE EYE/INTERUPT held more than 3 minutes
Check wired input on main control board Check for
alignment or obstruction
YES
62
CLOSE EYE/EDGE held more than 3 minutes
63
OPEN EYE EDGE held more than 3 minutes
64
CLOSE EYE/INTERUPT held more than 3 minutes
Check wired input on expansion board Check for alignment
or obstruction
YES
65
CLOSE EYE/EDGE held more than 3 minutes
66
OPEN EYE EDGE held more than 3 minutes
67
Wireless Edge triggered for more than 3 minutes
Check wired input for wiring issue or obstruction
YES
68
Wireless Edge loss of monitoring
Check Wireless Edge inputs
YES
69
Wireless Edge triggered
IF an obstruction occurred, no action required. If an
obstruction DID NOT occur, check inputs and wiring
NO
70
CLOSE EYE/INTERUPT triggered, causing reversal,
preventing close, or resetting TTC
IF an obstruction occurred, no action required. If an
obstruction DID NOT occur, check inputs and wiring on main
control board
NO
71
CLOSE EDGE triggered, causing reversal, preventing
close, or resetting TTC
72
OPEN EYE/EDGE triggered, causing reversal,
preventing close, or resetting TTC
73
CLOSE EYE/INTERUPT triggered, causing reversal,
preventing close, or resetting TTC
IF an obstruction occurred, no action required. If an
obstruction DID NOT occur, check inputs and wiring on
expansion board
NO
74
CLOSE EDGE triggered, causing reversal, preventing
close, or resetting TTC
75
OPEN EYE/EDGE triggered, causing reversal,
preventing close, or resetting TTC
80
Close Input (EYE/EDGE) communication fault from
operator
Check inputs and communication methods between
operators, either wired, bus, or radio. Ensure operator is
powered.
May have to erase the wireless communication and
reprogram the two operators.
YES
81
Open Input (EYE/EDGE) communication fault from
operator
82
Close Input (EYE/EDGE) communication fault
(expansion board)
Check the connections between the main board and the
expansion board.
YES
83
Open Input (EYE/EDGE) communication fault
(expansion board)
MPORTANT NOTE:
If a problem is found with an installation, be sure to read the troubleshooting guide thoroughly. If the problem persists call Chamberlain for
technical assistance on 1800 638 234 or email [email protected] in Australia or in New Zealand call 0800 653 667.
See S-Drive manual on how to view error codes.
TROUBLESHOOTING