SAFETY INSTRUCTIONS

 WARNING: 

THESE ARE IMPORTANT SAFETY INSTRUCTIONS. 

FOLLOW ALL INSTRUCTIONS AS INCORRECT INSTALLATION CAN LEAD TO SEVERE INJURY OR DEATH

SAVE these instructions

CAUTION

The equipment has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict 

accordance with the instructions and warnings contained in this manual.

When you see this Signal Word on the following pages, it will alert you to the 

possibility of damage to your commercial door and/or the commercial door operator 

if you do not comply with the cautionary statements that accompany it.

• 

Keep commercial door balanced. Sticking or binding doors must be repaired. Commercial doors, door springs, pulleys, brackets 

and their hardware are under extreme tension and can cause serious personal injury. Do not attempt to loosen, move or adjust 

them. Call for commercial door service.

 

• 

Do not wear rings, watches or loose clothing while installing or servicing a commercial door operator.

• 

To avoid serious personal injury from entanglement, remove all ropes connected to the commercial door before installing the door 

operator.

• 

After the installation a final test of the full function of the system and the full function of the safety devices must be done.

• 

When operating a biased-off switch, make sure that other persons are kept away.

• 

The operator cannot be used with a driven part incorporating a wicket door (unless the operator cannot be operated with the 

wicket door open).

• 

Operator may become hot during operation. Appropriate clearance and/or shielding should be supplied by the installer to ensure 

any cabling, wiring and/or other items cannot come in contact with the operator. If temperature rise exceeds 50°C all fixed wiring 

insulation must be protected, for example, by insulating sleeving having an appropriate temperature rating.

• 

Do not allow children to play with operator wall controls or remote transmitters.  Keep remote transmitters away from children.

• 

Permanently fasten all supplied labels adjacent to the wall control as a convenient reference and reminder of safe operating 

procedures.

• 

Disengage all existing commercial door locks to avoid damage to commercial door. Install the wall control (or any additional push 
buttons) in a location where the commercial door is visible during operation . Do not allow children to operate push button(s) or 
remote transmitter(s). Serious personal injury from a closing commercial door may result from misuse of the operator.

• 

Activate operator only when the door is in full view, free of obstructions and operator is properly adjusted. No one should enter or 

leave the building while the door is in motion.

• 

The actuating member of a biased-off switch is to be located within direct sight of the door but away from moving parts. Unless it 

is key operated, it is to be installed at a minimum height of 1500mm and not accessible to the public.

• 

Make sure that people who install, maintain or operate the door follow these instructions. Keep these instructions in a safe place so 

that you can refer to them quickly when you need to.

• 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person 

responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

• 

Use the operator for its intended purpose. GLM6 series controls are designed for operating Grifco operators on spring balanced 

roller shutters, spring balanced roller doors and counterweighted bi-fold and vertical lift doors.

• 

If the operator is installed at a height less than 2.5 metres from floor level or any other level from which the unit can be accessed 

(eg mezzanine) the installer is responsible to fit guards to the operator to prevent access to the chain drive.

• 

Automatic Drive - Keep away from the area of the door as it may operate unexpectedly.

• 

Ensure that entrapment when operating the door in the open direction is avoided.

• 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to 

avoid a hazard.

• 

Installation and wiring must be in compliance with your local building and electrical codes. Connect the power supply cord only to 

properly earthed mains.

• 

Moisture and water can destroy the electronic components. Make sure under all circumstances that water moisture or storage 

moisture cannot penetrate the electronics. The same applies for openings and cable entries.

• 

An electrician must disconnect electric power to the commercial door operator before making repairs or removing covers.

WARNING

Electrical

When you see this Safety Symbol and Signal Words on the following pages, they will alert you to 

the possibility of serious injury or death if you do not comply with the warnings that accompany 

them. The hazard may come from electric shock.

WARNING

Mechanical

When you see this Safety Symbol and Signal Words on the following pages, they will alert you 

to the possibility of serious injury or death if you do not comply with the warnings that 

accompany them. The hazard may come from something mechanical.

Содержание GPS15

Страница 1: ...IFCO www grifco com au Ref D M ACG 070B GPS15 Installation and Users Manual for GPS15 Grifco Protector System 15 Metre Monitored Reflective PE Beam Kit INSTRUCTION MANUAL Chamberlain New Zealand Ltd 1...

Страница 2: ...ECTRICAL CONNECTION EDRIVE AND GLM 8 EDRIVE AND GLM DIP SWITCH SETTING AND DOOR BEHAVIOUR 8 ELECTRICAL CONNECTION SDRIVE 9 ELECTRICAL CONNECTION LSDRIVE 10 ELECTRICAL CONNECTION LRDRIVE 11 ELECTRICAL...

Страница 3: ...mage to property WARNING After the installation a final test of the full function of the system and where present the full function of the safety devices must be performed Do not place hands or tools...

Страница 4: ...door is in full view free of obstructions and operator is properly adjusted No one should enter or leave the building while the door is in motion The actuating member of a biased off switch is to be...

Страница 5: ...an IP67 rating The images are for reference and your product may look different Please note The GPS15 is only compatible with the Grifco or Merlin products listed below Use with ANY other product void...

Страница 6: ...15 with bi fold doors position the photoelectric sensor and reflector so that the door does not break the beam as it is operated No part of the door or door tracks springs hinges rollers or other hard...

Страница 7: ...r Use 5 5mm or 6mm masonry drill bits and 6mm green wall plugs and screws to install the bracket to the wall The photoelectric sensor and the reflector should be mounted at the same height from the fl...

Страница 8: ...0 seconds or until the green LED on the MCB blinks rapidly WARNING DO NOT CONNECT THE GPS15 to VDC OUT The GPS15 must be connected to the IR1 or IR2 terminals only of the operator Connection to a volt...

Страница 9: ...pen direction When an obstruction is detected during opening the door will stop and travel down for 2 seconds This input will be disregarded during closing Open Eyes Edges can be used on doors that ma...

Страница 10: ...ug Using a small flat blade screwdriver loosen the screws on the quick connect plug and remove the cables from the plug The plug is not needed As this product is polarity sensitive ensure the Brown wi...

Страница 11: ...ct plug and remove the cables from the plug The plug is not needed As this product is polarity sensitive ensure the Brown wire is terminated into terminal number 6 and the blue wire is terminated into...

Страница 12: ...n the screws on the quick connect plug and remove the cables from the plug The plug is not needed As this product is polarity sensitive ensure the Brown wire is terminated into terminal number 4 and t...

Страница 13: ...ing a small flat blade screwdriver loosen the screws on the quick connect plug and remove the cables from the plug The plug is not needed As this product is polarity sensitive ensure the Brown wire is...

Страница 14: ...loosen the screws on the quick connect plug and remove the cables from the plug The plug is not needed As this product is polarity sensitive ensure the Brown wire is terminated into terminal number 5...

Страница 15: ...ve Now remove the obstacle and give the operator a close command The door should close Introduce an obstruction into the path of the photoelectric sensor and the door should stop and reverse Rotate th...

Страница 16: ...4 Direction error Motor connections altered Change door direction and reset limits 15 Clutch slip if fitted No speed detected Contactor failure Clutch adjustment set too low Motor stalled Extreme vibr...

Страница 17: ...flashing after third press of the set button YES But green status light starts to flash x times while attempting to set upper limit Refer Troubleshooting pg 16 NO Ensure all external devices and exte...

Страница 18: ...venting close or resetting TTC 72 OPEN EYE EDGE triggered causing reversal preventing close or resetting TTC 73 CLOSE EYE INTERUPT triggered causing reversal preventing close or resetting TTC IF an ob...

Страница 19: ...ed or cut wire Turn power off and reboot the operator 1 2 The garage door operator will not close and the courtesy light flashes There is a short circuit on the wire for the safety sensors Inspect saf...

Страница 20: ...nty claim has been made in respect of a failure or defect arising under or out of any exclusion detailed below such that the claim is not covered under this Chamberlain Limited Warranty we may subject...

Отзывы: