Contents 

1

 

Intended use ..................................................................................................... 2

 

2

 

General note ..................................................................................................... 2

 

3

 

Disposal notes .................................................................................................. 2

 

4

 

Safety instructions ............................................................................................ 3

 

5

 

Operating and maintenance advice ................................................................. 4

 

6

 

Operation .......................................................................................................... 4

 

7

 

Oxygen measuring ........................................................................................... 5

 

8

 

Calibration ........................................................................................................ 5

 

9

 

Sensor rating .................................................................................................... 6

 

10

 

Replace sensor element................................................................................... 6

 

11

 

Errors and system messages ........................................................................... 6

 

12

 

Display when switching-on the device ............................................................. 6

 

13

 

Configuration of the device .............................................................................. 7

 

14

 

Specification ..................................................................................................... 8

 

 
 

Intended use 

This device measures the oxygen concentration in gas mixtures and air. The actual 
measurement takes place at the opening of the sensor. Due to the design of the 
sensor, the device has to be calibrated at regular intervals (at fresh air =20.95% 
oxygen) to get accurate measuring values. If the sensor is used up, this will be 
detected at calibration and the sensor element has to be replaced before the next 
measurement. 

General note 

Read this document carefully and get used to the handling of the device before you 
use it. Keep this paper ready to hand in order to look it up if a question turns up. 

Disposal notes 

 

Dispense exhausted batteries at destined gathering places. 
This device and the sensor must not be disposed as ‘residual waste’. 
According to the ElektroG 

(law for bringing into market, the return and the 

environmentally friendly disposal of electronic equipment)

 we accept the 

return of this device and/or the sensor, please send it directly to us 
(adequately stamped). We will dispose it appropriately and 
environmentally friendly.

 

 

 

Содержание GOX 100

Страница 1: ...H Messtechnik GmbH Standort Greisinger Hans Sachs Stra e 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Oxygen Measuring Device WEEE Reg Nr DE 93889386 as of V1 3 Operatin...

Страница 2: ...t fresh air 20 95 oxygen to get accurate measuring values If the sensor is used up this will be detected at calibration and the sensor element has to be replaced before the next measurement 2 General...

Страница 3: ...y to avoid re starting Operator safety may be a risk if there is visible damage to the device or the device is not working as specified the device has been stored under unsuitable conditions for a lon...

Страница 4: ...d Operation elements 1 display of the oxygen concentration in 2 BAT warning battery is used up and has to be replaced measuring is valid On Off switch Press shortly change between display of actual va...

Страница 5: ...rong air flows can produce an over pressure at the sensor possible source of measuring calibration errors The nominal life time can be shortened by Wrong storage operation temperature Permanent use wi...

Страница 6: ...it down and plug it Then start the calibration 11 Errors and system messages no display The battery is used up and has to be exchanged or the device is defective The battery is used up for a short pe...

Страница 7: ...ing 980 mbar Enter the absolute air pressure or pressure of the gas that is measured Its value depends on your altitude see the table below and the present weather 5 Press the key the current value ap...

Страница 8: ...ax Memory min and max measured value are stored Nominal temp 25 C Ambient temp 0 to 45 C sensor 20 to 50 C device Relative humidity 0 to 95 RH not condensing Storage temperature 15 to 60 C sensor 20 t...

Отзывы: