Safety instructions 

This device has been designed and tested in accordance to the safety regulations 
for electronic devices. However, its trouble-free operation and reliability cannot be 
guaranteed unless standard safety measures and special safety advises given in 
this manual will be adhered to when using it. 

1.  Trouble-free operation and reliability of the device can only be guaranteed if it 

is not subjected to any other climatic conditions than those stated under 
“Specification”. 

2.  Transporting the device from a cold to a warm environment condensation may 

result in a failure of the function. In such a case make sure the device 
temperature has adjusted to the ambient temp. before trying a new start-up. 

3.  The circuitry has to be designed most carefully if the device should be 

connected to other devices. Internal connection in third party devices (e.g. 
connection GND and earth) may result in not-permissible voltages impairing or 
destroying the device or another device connected. 

4.  Whenever there may be a risk whatsoever involved in running it, the device 

has to be switched off immediately and to be marked accordingly to avoid re-
starting. Operator safety may be a risk if: 
- there is visible damage to the device or the device is not working as specified. 
- the device has been stored under unsuitable conditions for a longer time. 
In case of doubt, please return device to manufacturer for repair or 
maintenance. 

5. 

Warning: 

Do not use this product as safety or emergency stop device or in 

other applications where failure of the product could result in personal injury or 
material damage. Failure to comply with these instructions could result in death 
or serious injury and material damage. 

6.  This device only serves as supervision by the monitoring of essential or other 

for the customer important systems. 
It must not be used instead of compulsory approval monitoring devices and it is 
not designed for that purpose. If this device is used for the monitoring of such 
systems on its own, the manufacturer will not assume liability for damages 
whatsoever. 

7. 

Caution, acid!

 The sensor contains KOH. This can cause severe chemical 

burns.  If leaking, avoid contact! 

If there was contact:

 

- to skin: Flush contacted area with large amounts of water 
for several minutes. 
- to clothing: remove contaminated clothing. 
- to eyes: Flush with large amounts of water for several 
  minutes, obtain medical treatment. 

After swallowing:

 

- give large volumes of water. DO NOT induce vomiting! 
- Obtain medical treatment. 

 

 

Содержание GOX 100

Страница 1: ...H Messtechnik GmbH Standort Greisinger Hans Sachs Stra e 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Oxygen Measuring Device WEEE Reg Nr DE 93889386 as of V1 3 Operatin...

Страница 2: ...t fresh air 20 95 oxygen to get accurate measuring values If the sensor is used up this will be detected at calibration and the sensor element has to be replaced before the next measurement 2 General...

Страница 3: ...y to avoid re starting Operator safety may be a risk if there is visible damage to the device or the device is not working as specified the device has been stored under unsuitable conditions for a lon...

Страница 4: ...d Operation elements 1 display of the oxygen concentration in 2 BAT warning battery is used up and has to be replaced measuring is valid On Off switch Press shortly change between display of actual va...

Страница 5: ...rong air flows can produce an over pressure at the sensor possible source of measuring calibration errors The nominal life time can be shortened by Wrong storage operation temperature Permanent use wi...

Страница 6: ...it down and plug it Then start the calibration 11 Errors and system messages no display The battery is used up and has to be exchanged or the device is defective The battery is used up for a short pe...

Страница 7: ...ing 980 mbar Enter the absolute air pressure or pressure of the gas that is measured Its value depends on your altitude see the table below and the present weather 5 Press the key the current value ap...

Страница 8: ...ax Memory min and max measured value are stored Nominal temp 25 C Ambient temp 0 to 45 C sensor 20 to 50 C device Relative humidity 0 to 95 RH not condensing Storage temperature 15 to 60 C sensor 20 t...

Отзывы: