Safety instructions
This device has been designed and tested in accordance to the safety regulations
for electronic devices. However, its trouble-free operation and reliability cannot be
guaranteed unless standard safety measures and special safety advises given in
this manual will be adhered to when using it.
1. Trouble-free operation and reliability of the device can only be guaranteed if it
is not subjected to any other climatic conditions than those stated under
“Specification”.
2. Transporting the device from a cold to a warm environment condensation may
result in a failure of the function. In such a case make sure the device
temperature has adjusted to the ambient temp. before trying a new start-up.
3. The circuitry has to be designed most carefully if the device should be
connected to other devices. Internal connection in third party devices (e.g.
connection GND and earth) may result in not-permissible voltages impairing or
destroying the device or another device connected.
4. Whenever there may be a risk whatsoever involved in running it, the device
has to be switched off immediately and to be marked accordingly to avoid re-
starting. Operator safety may be a risk if:
- there is visible damage to the device or the device is not working as specified.
- the device has been stored under unsuitable conditions for a longer time.
In case of doubt, please return device to manufacturer for repair or
maintenance.
5.
Warning:
Do not use this product as safety or emergency stop device or in
other applications where failure of the product could result in personal injury or
material damage. Failure to comply with these instructions could result in death
or serious injury and material damage.
6. This device only serves as supervision by the monitoring of essential or other
for the customer important systems.
It must not be used instead of compulsory approval monitoring devices and it is
not designed for that purpose. If this device is used for the monitoring of such
systems on its own, the manufacturer will not assume liability for damages
whatsoever.
7.
Caution, acid!
The sensor contains KOH. This can cause severe chemical
burns. If leaking, avoid contact!
If there was contact:
- to skin: Flush contacted area with large amounts of water
for several minutes.
- to clothing: remove contaminated clothing.
- to eyes: Flush with large amounts of water for several
minutes, obtain medical treatment.
After swallowing:
- give large volumes of water. DO NOT induce vomiting!
- Obtain medical treatment.