Operating and maintenance advice 

  The battery has to be taken out, when the device is stored above 50°C. 
  Handle the device and the sensor with care and only use it according its 

specification. The connectors have to be saved from humidity and dirt.  

  Unplug the sensor not by pulling the cable, but the plug.  

Tip: It is recommended to take the battery out, when the device is stored for a 

longer period of time. 

 

Operation 

Display- and Operation elements 

 

1.  display of the oxygen concentration in %  
2.  BAT-warning: battery is used up and has to be 

replaced (measuring is valid) 

 

 

On/Off switch

  

 

Press shortly: change between 

display of actual value

-,                                                  

:Min-value display,

                                                   

:Max- value display 

Press long:     delete min/max values 

 

Press shortly: short display of the sensor rating (calculated after the last 

calibration) (i.e. “100.P“ = 100%) 

Press long:     start calibration (see also calibration) 

First start 

If not already done: plug the sensor to the device. 

Switch the device on with the

 

 key. 

Start the calibration by pressing the

 

 key for 2 seconds, until 

 is 

displayed. After the calibration the device is ready for measuring.  

 

 

Содержание GOX 100

Страница 1: ...H Messtechnik GmbH Standort Greisinger Hans Sachs Stra e 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Oxygen Measuring Device WEEE Reg Nr DE 93889386 as of V1 3 Operatin...

Страница 2: ...t fresh air 20 95 oxygen to get accurate measuring values If the sensor is used up this will be detected at calibration and the sensor element has to be replaced before the next measurement 2 General...

Страница 3: ...y to avoid re starting Operator safety may be a risk if there is visible damage to the device or the device is not working as specified the device has been stored under unsuitable conditions for a lon...

Страница 4: ...d Operation elements 1 display of the oxygen concentration in 2 BAT warning battery is used up and has to be replaced measuring is valid On Off switch Press shortly change between display of actual va...

Страница 5: ...rong air flows can produce an over pressure at the sensor possible source of measuring calibration errors The nominal life time can be shortened by Wrong storage operation temperature Permanent use wi...

Страница 6: ...it down and plug it Then start the calibration 11 Errors and system messages no display The battery is used up and has to be exchanged or the device is defective The battery is used up for a short pe...

Страница 7: ...ing 980 mbar Enter the absolute air pressure or pressure of the gas that is measured Its value depends on your altitude see the table below and the present weather 5 Press the key the current value ap...

Страница 8: ...ax Memory min and max measured value are stored Nominal temp 25 C Ambient temp 0 to 45 C sensor 20 to 50 C device Relative humidity 0 to 95 RH not condensing Storage temperature 15 to 60 C sensor 20 t...

Отзывы: