GREISINGER GMH 5450 Скачать руководство пользователя страница 4

H83.0.01.6C-6 

 Operating manual GMH 5450 

page 4 of 20 

 

 

_____________________________________________________ 

_____________________________________________________________________________ 

 

 

2.    

 

If there is a risk whatsoever involved in running it, the device has to be switched off 
immediately and to be marked accordingly to avoid re-starting. 
Operator safety may be a risk if: 
- there is visible damage to the device 
- the device is not working as specified 
- the device has been stored under unsuitable conditions for a longer time. 
In case of doubt, please return device to manufacturer for repair or maintenance. 

3.  When connecting the device to other devices the connection has to be designed most thoroughly as 

internal connections in third-party devices (e.g. connection GND with protective earth) may lead to 
undesired voltage potentials that can lead to malfunctions or destroying of the GMH 5155 and the 
connected devices. 

 

This device must not be run with a defective or damaged power supply unit.  
Danger to life due to electrical shock!  
 

 

4. 

 

 

Do not use these products as safety or emergency stop devices or in any other application 
where failure of the product could result in personal injury or material damage. 
Failure to comply with these instructions could result in death or serious injury and material 
damage. 

 

5. 

 

 

This device must not be used at potentially explosive areas! The usage of this device at 
potentially explosive areas increases danger of deflagration, explosion or fire due to 
sparking. 

 

Product Specification 

3.1  Scope of supply 

The scope of supply includes:  

  GMH 5450 with 2 AAA batteries 
  Operating manual 
  Short form manual 

3.2  Operation and maintenance advice 

1.  Battery operation: 

If ‘bAt’ is shown in the lower display the battery has been used up and needs to be replaced. However, 
the device will operate correctly for a certain time. If ‘bAt’ is shown in the upper display the voltage is too 
low to operate the device; the battery has been completely used up. Battery change: p.r.t. chapter 

Fehler! 

erweisquelle konnte nicht gefunden werden.

The battery has to be taken out, when storing device above 50°C. We recommend taking out 
battery if device is not used for a longer period of time. 
After recommissioning the real-time clock has to be set again.  

2.  Treat device and sensor carefully. Use only in accordance with above specification. (do not throw, hit 

against etc.). Protect plug and socket from soiling. 

3.  USB or mains operation: 

When connecting a mains cable or USB interface cable, please take care to connect only allowed 
components. 

The output voltage of a connected power supply unit has to be between 4.5 and 5.5 V DC. 
Don’t apply overvoltage!   

We recommend operation with interface cable USB 5100. Then device is supplied by the USB interface of 
the connected PC or USB power supply adapter. 

 

 

 

 

 

 

 

Содержание GMH 5450

Страница 1: ...9402 9383 0 49 0 9402 9383 33 info greisinger de as of version 1 9 GMH 5450 WEEE Reg Nr DE 93889386 Operating manual Conductivity measuring device water proof with data logger Please carefully read th...

Страница 2: ...UREMENT 8 6 7 ELECTRODES MEASURING CELLS 9 6 7 1 Assignment bayonet connector 9 6 7 2 Design and selection 9 6 8 TEMPERATURE COMPENSATION 9 6 8 1 Temperature compensation nLF according to EN 27888 9 6...

Страница 3: ...pole bayonet socket Generally a suitable temperature sensor is included to the electrode The measured temperature is used for the automatic temperature compensation e g Lin or nlF and is additionally...

Страница 4: ...ial damage 5 This device must not be used at potentially explosive areas The usage of this device at potentially explosive areas increases danger of deflagration explosion or fire due to sparking 3 Pr...

Страница 5: ...re compensation 7 K 1 cm additional configuration units 8 logg arrow logger is ready arrow flashing automatic recording Logg CYCL is active 4 2 Pushbuttons On off key backlight press shortly activate...

Страница 6: ...ndling Pull at label open in order to swing open the pop up clip Pull at label open again to swing open the pop up clip further Pop up clip closed Pop up clip at position 90 Pop up clip at position 18...

Страница 7: ...cell constant K Application 0 01 0 004000 0 015000 1 cm Ultra pure water electrodes with K 0 01 0 1 0 04000 0 15000 1 cm Ultra pure water electrodes with K 0 1 1 0 4000 1 5000 1 cm Standard electrode...

Страница 8: ...NaCl KCl etc 0 50 Natural waters surface waters drinking water 0 65 0 70 e g salt concentration of aqueous fertilizer solutions Attention This are only approximate values good for estimations but no...

Страница 9: ...for used in petrol diesel etc with low conductivities 1000 S cm LF 210 6 8 Temperature compensation The conductivity of aqueous solutions depends on its temperature The temperature dependency is stron...

Страница 10: ...ed for more than 2 minutes the configuration will be aborted All changes will be discarded Menu Parameter Value Description or rEAd Logg Read manual recordings see chapter 8 1 Manual recording Func St...

Страница 11: ...ure compensation Compensation coefficient only if t Cor Lin 0 300 3 000 Temperature compensation coefficient in K Reference temperature of temperature compensation only if t Cor Lin or nLF 25 C 77 F R...

Страница 12: ...in Set Alarm Configuration of alarm function On No So Measuring channel cond rES TDS SAL alarm on with buzzer without buzzer OFF No alarm function for measuring channel cond rES TDS SAL 0 0000 S cm 1...

Страница 13: ...ly used for the operation of the logger functions 8 1 Manual recording Func Stor a Save measurements manually Up to 1000 measurements can be saved if logger function Func store is selected see Configu...

Страница 14: ...rage process is signaled by shortly displaying St XXXXX where XXXXX is the number of the saved data set If the logger memory is full the recording stops automatically and the display shows b Stop reco...

Страница 15: ...ur own software we offer a GMH3000 development package including a universally applicable Windows functions library GMH3x32e DLL with documentation can be used by all established programming languages...

Страница 16: ...re known by the device and are compensated automatically Press Cal key for 2 s start of calibration actual value e g 1823 S cm value of solution e g 1413 S cm and CAL with rotary symbol and CAL with r...

Страница 17: ...ut the interval after which the device reminds you to recalibrate The interval times should be chosen according to the application and the stability of the electrode CAL flashes on the display as soon...

Страница 18: ...tings can only be checked and if necessary corrected by the manufacturer A calibration protocol is enclosed to the device ex works This documents the precision reached by the production process 16 Rep...

Страница 19: ...evice CAL CAL flashing in upper display Either preset calibration interval has expired or last calibration is not valid Device has to be calibrated NO AVTO LO66 RAN6 Logger could not be started Auto r...

Страница 20: ...ext supply 4 pole bayonet socket for serial interface and supply USB Adapter USB 5100 Analog output 0 1V adjustable Display 4 digit 7 segment illuminated white Add functions Min max hold function Adju...

Отзывы: