GREISINGER GMH 5450 Скачать руководство пользователя страница 14

H83.0.01.6C-6 

 Operating manual GMH 5450 

page 14 of 20 

 

 

_____________________________________________________ 

_____________________________________________________________________________ 

 

 

 

Clear the latest data set 

 

Confirm selection and quit menu “Clear” 

8.2  Automatic 

recording with selectable cycle time “Func CYCL” 

If logger function “Func CYCL” is selected (see “Configuration”) the device will automatically record 
measuring values at intervals of the set cycle time.  
The logger’s cycle time can be set from 1s to 60min (see “Configuration”).  

Up to 10000 measurements can be saved if logger function “Func CYCL” is selected. 

a) Start recording: 

 

Press “store” for 2 seconds:

 Start menu, press 

 again: automatic recording is started 

Each storage process is signaled by 

shortly displaying “St.XXXXX”, where XXXXX is the number of the 

saved data set. 

If the logger memory is full, the recording stops automatically and the display shows 

b) 

Stop recording: 

 

Press “store” for 2 seconds:

 

If recording is running the “stop” menu is displayed  

Select with 

 or 

 

 

Do not stop recording (cancel) 

 

 

Stop recording

 

 

If recording is running the “stop” menu is displayed  

 

  

 If you try to switch off the device while cyclic recording is active you will be asked 

whether the recording should really be stopped.  
The device can only be switched off if the recording is stopped. Auto-off function is 
deactivated as long as cyclic recording is active.   

c) Clear recordings: 

 

Press “store” for 2 seconds:

  

If there are data sets stored and recording is already stopped the menu “Clear” is displayed  

Select with 

 or 

.  

 

 

Clear nothing (cancel) 

 

 

Clear all data sets

 

 

 

Clear latest data set 

 

Confirm selection and quit menu “Clear”  

 
  

 

 

Содержание GMH 5450

Страница 1: ...9402 9383 0 49 0 9402 9383 33 info greisinger de as of version 1 9 GMH 5450 WEEE Reg Nr DE 93889386 Operating manual Conductivity measuring device water proof with data logger Please carefully read th...

Страница 2: ...UREMENT 8 6 7 ELECTRODES MEASURING CELLS 9 6 7 1 Assignment bayonet connector 9 6 7 2 Design and selection 9 6 8 TEMPERATURE COMPENSATION 9 6 8 1 Temperature compensation nLF according to EN 27888 9 6...

Страница 3: ...pole bayonet socket Generally a suitable temperature sensor is included to the electrode The measured temperature is used for the automatic temperature compensation e g Lin or nlF and is additionally...

Страница 4: ...ial damage 5 This device must not be used at potentially explosive areas The usage of this device at potentially explosive areas increases danger of deflagration explosion or fire due to sparking 3 Pr...

Страница 5: ...re compensation 7 K 1 cm additional configuration units 8 logg arrow logger is ready arrow flashing automatic recording Logg CYCL is active 4 2 Pushbuttons On off key backlight press shortly activate...

Страница 6: ...ndling Pull at label open in order to swing open the pop up clip Pull at label open again to swing open the pop up clip further Pop up clip closed Pop up clip at position 90 Pop up clip at position 18...

Страница 7: ...cell constant K Application 0 01 0 004000 0 015000 1 cm Ultra pure water electrodes with K 0 01 0 1 0 04000 0 15000 1 cm Ultra pure water electrodes with K 0 1 1 0 4000 1 5000 1 cm Standard electrode...

Страница 8: ...NaCl KCl etc 0 50 Natural waters surface waters drinking water 0 65 0 70 e g salt concentration of aqueous fertilizer solutions Attention This are only approximate values good for estimations but no...

Страница 9: ...for used in petrol diesel etc with low conductivities 1000 S cm LF 210 6 8 Temperature compensation The conductivity of aqueous solutions depends on its temperature The temperature dependency is stron...

Страница 10: ...ed for more than 2 minutes the configuration will be aborted All changes will be discarded Menu Parameter Value Description or rEAd Logg Read manual recordings see chapter 8 1 Manual recording Func St...

Страница 11: ...ure compensation Compensation coefficient only if t Cor Lin 0 300 3 000 Temperature compensation coefficient in K Reference temperature of temperature compensation only if t Cor Lin or nLF 25 C 77 F R...

Страница 12: ...in Set Alarm Configuration of alarm function On No So Measuring channel cond rES TDS SAL alarm on with buzzer without buzzer OFF No alarm function for measuring channel cond rES TDS SAL 0 0000 S cm 1...

Страница 13: ...ly used for the operation of the logger functions 8 1 Manual recording Func Stor a Save measurements manually Up to 1000 measurements can be saved if logger function Func store is selected see Configu...

Страница 14: ...rage process is signaled by shortly displaying St XXXXX where XXXXX is the number of the saved data set If the logger memory is full the recording stops automatically and the display shows b Stop reco...

Страница 15: ...ur own software we offer a GMH3000 development package including a universally applicable Windows functions library GMH3x32e DLL with documentation can be used by all established programming languages...

Страница 16: ...re known by the device and are compensated automatically Press Cal key for 2 s start of calibration actual value e g 1823 S cm value of solution e g 1413 S cm and CAL with rotary symbol and CAL with r...

Страница 17: ...ut the interval after which the device reminds you to recalibrate The interval times should be chosen according to the application and the stability of the electrode CAL flashes on the display as soon...

Страница 18: ...tings can only be checked and if necessary corrected by the manufacturer A calibration protocol is enclosed to the device ex works This documents the precision reached by the production process 16 Rep...

Страница 19: ...evice CAL CAL flashing in upper display Either preset calibration interval has expired or last calibration is not valid Device has to be calibrated NO AVTO LO66 RAN6 Logger could not be started Auto r...

Страница 20: ...ext supply 4 pole bayonet socket for serial interface and supply USB Adapter USB 5100 Analog output 0 1V adjustable Display 4 digit 7 segment illuminated white Add functions Min max hold function Adju...

Отзывы: