Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF

          Page 3 of 14

1. Safety regulations

This device was designed and tested considering the safety regulations for electronic measuring devices.
Faultless operation and reliability in operation of the measuring device can only be assured if the General
Safety Measures and the devices specific safety regulations mentioned in this users manual are considered.
1.  Faultless operation and reliability in operation of the measuring device can only be assured if the device

is used within the climatic conditions specified in the chapter “Specification“

2. Always disconnect the device from its supply before opening it. Take care that nobody can touch any of

the devices contacts after installing the device.

3. Standard regulations for operation and safety for electrical, light and heavy current equipment have to be

observed, with particular attention paid to the national safety regulations (e.g. VDE 0100).

4. When connecting the device to other devices (e.g. the PC) the interconnection has to be designed most

thoroughly, as internal connections in third-party devices (e.g. connection of ground with protective earth)
may lead to undesired voltage potentials.

5. The device must be switched off and must be marked against re-starting, in case of obvious malfunctions

of the device which are e.g.:

-

 visible 

damage.

-

 

the device is not working as prescribed.

-

 

after storage of the device under inappropriate conditions for longer time.

In case of doubt, the device should be sent to the manufacturer for repairing or servicing.

 ATTENTION:

 When running electric devices, parts of them will always be electrically

live. Unless the warnings are observed serious personal injuries or damage to prop-
erty may result. Skilled personnel only should be allowed to work with this device. For
trouble-free and safe operation of the device please ensure professional transport,
storage, installation and connection as well as proper operation and maintenance.

SKILLED PERSONNEL

Are persons familiar with installation, connection, commissioning and operation of the product and have
professional qualification relating to their job.

For example:
 • Training or instruction respectivley qualifications to switch on or off, isolate, ground and mark electric cir-

cuits and devices or systems.

 • Training or instruction according to the state.
 • First-aid training.

  

ATTENTION:

Do NOT use this product as safety or emergency stopping device, or in any other ap-
plication where failure of the product could result in personal injury or material dam-
age.

Failure to comply with these instructions could result in death or serious injury and
material damage.

Содержание GIR 230 NTC / DIF

Страница 1: ...E33 0 31 6C 02 Manual for connection and operation of the GIR230 Pt1000 DIF and GIR230 NTC DIF Page 1 of 14 Manual for connection and operation of GIR 230 Pt1000 DIF GIR 230 NTC DIF Version 1 3...

Страница 2: ...relay outputs 5 3 4 2 Connection of output 3 NPN output switching to ground 5 4 CONFIGURATION OF THE DEVICE 6 4 1 Selecting an input signal type 6 4 2 Selection of the output function 7 5 SWITCHPOINT...

Страница 3: ...he device must be switched off and must be marked against re starting in case of obvious malfunctions of the device which are e g visible damage the device is not working as prescribed after storage o...

Страница 4: ...factory the GIR230 has been subjected to various inspection tests and is completely cali brated Before the GIR230 can be used it has to be configured for the customer s application Hint In order to av...

Страница 5: ...switching outputs properly Please take care that you must not exceed the limits of the voltage and of the maximum current of the switching outputs not even for a short period of time Please take extr...

Страница 6: ...the device switches to the lower limit vice versa 4 1 Selecting an input signal type Turn the device on and wait until it completed its built in segment test Press button 2 for 2 sec The display will...

Страница 7: ...you have to configure the preferred states and delay time of the outputs and the switch and alarm points Depending on your output function setting it may be possible that one or more settings describ...

Страница 8: ...ss button 1 when not already done The device will be displaying 1 on turn on point of output 1 Use button 2 and button 3 to set the desired value the device s output 1 should be turning on Press butto...

Страница 9: ...points for the second switching function 2 on 2 off Configuring these settings like the first switching function After that the alarm outputs have to be configured When pressing button 1 the device w...

Страница 10: ...stays above 50 C for the entered delay time or after it had been falling below 15 C and stays below 15 C for the entered delay time Please note that the alarm outputs are inverted This means that the...

Страница 11: ...1 slope adjustment 1 100 Example The setting is 2 00 the slope has risen 2 00 slope 102 When measuring a value of 1000 without slope adjustment the device would display 1020 with slope adjustment of 1...

Страница 12: ...s check probe and device configuration Err 7 System error The device features an integrated self diagnostic function which checks essential parts of the de vice permanently When detecting a failure er...

Страница 13: ...ty 5A 230VAC resistive load NPN output NPN Open Collector breaking capacity 30mA max 28VDC Output functions 2 point 3 point 2 point with alarm 3 point with alarm min max alarm Switching points arbitra...

Страница 14: ...E33 0 31 6C 02 Manual for connection and operation of the GIR230 Pt1000 DIF and GIR230 NTC DIF Page 14 of 14...

Отзывы: