IMPORTANT - PLEASE READ MANUAL BEFORE INSTALLATION

CONTENTS 

TO REDUCE OR AVOID THE HAZARDS OF ELECTRIC SHOCK AND FIRE:     

CAUTIONS CONCERNING THE OPERATION AND FULL EFFICIENCY OF THIS PRODUCT:

CAUTION:

 Do not install in a cooking area or connect directly to any appliance. Turn off all integral disconnects before servicing.

NOTICE:

   Prior to installing, serious consideration must be taken to insure this ventilation system will operate properly if integrated to any other type of 

mechanical system, i.e. a forced air system, or an air handling unit. To insure proper operation & compatibilities of both system, it is required that the airflow’s of 

the Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV) be balanced, by following the procedures found in this manual.
The way that your Heat/Energy-recovery ventilator is installed may make a significant difference to the electrical energy that you will use. To minimize the 

electricity use of the Heat/Energy-recovery ventilator, a stand-alone fully ducted installation is recommended. If you choose a simplified installation that operates 

your furnace airhandler for room-to-room ventilation, an electrically efficient furnace that has an electronically commutated (EC) variable speed blower motor will 

minimize your electrical energy consumption and operating cost.

LIMITATIONS:

 The product is for residential applications only. Must be installed in accordance with all national and local regulations, building and safety codes.

  SECTION 

PAGE

  1. Ventilation requirements . . . . . . . . . . . . . . . . . . . . . . . . . 3
  2. Fitting equivalent lengths .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 4
  3. Types of Installations .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 5
  4. Installation of the HRV / ERV . . . . . . . . . . . . . . . . . . . . . . . 7
  5. Insulated Flex from Unit to Outside Wall . . . . . . . . . . . . . . . . . 7
  6. Condensation Drain Line . . . . . . . . . . . . . . . . . . . . . . . . . 8
  7. Dedicated Electric Receptacle  . . . . . . . . . . . . . . . . . . . . . . 8
  8. Outside Fresh Air and Stale Air Hoods . . . . . . . . . . . . . . . . . . 8
  9. The matrix™ High Performance Ventilation Hood . . . . . . . . . . . . 9
  10. Benefits of the Duotrol™ System .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  9
  11. Balancing the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
  12. Controls Connection.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .12
  13. Wiring Diagrams for furnace interlock systems . . . . . . . . . . . . .13
  14. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
  15. Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
  16. Balancing Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

• Before servicing or cleaning the HRV system, always remove the power cord 

from the AC wall outlet.

• To reduce the hazards of electric shock or fire, do not perform any service 

to the HRV system other than those stated in the operating manual 

instructions.

• To reduce the risk of electric shock, this ventilation system (HRV/ERV) 

comes equipped with a 3-prong plug-in. This plug will fit in a polarized outlet 

only one way. 

• Do not use ventilation system for outdoor application.
• Do not pull or twist power cord when disconnecting it from the ventilation 

system. Grasp the plug firmly, not the cord.

• Do not modify the power plug in any way; if modified, risk of electric shock 

fire or even damage to the unit may occur.

• Do not use the ventilation system for removal of flammable fumes, gases or 

connect directly to any appliances.

• Use a dedicated AC 120V outlet only.
• Do not obstruct or cover the air intake or air outlet of the ventilation system.
• Do not modify, repair or disassemble this system. These tasks are to be 

performed by authorized serviced personnel only. Fire, electrical shock and/

or bodily injury may occur if these warnings are not followed.

• To prevent injuries, do not operate the ventilation system, while servicing 

or maintaining. There are impeller wheels turning at a very high speed that 

must fully stop rotating prior to accessing the inside of the unit.

• Always assess the operation of the ventilation system on how it may 

interact with vented combustion equipment (ie. Gas Furnace, Oil Furnace, 

Combustion, Appliances, etc.)

• Do not use for swimming pool/spa applications.

Содержание RNC 1.0 HRV

Страница 1: ...C 2 0 HRV Item No 463125 RNC 2 0ES HRV Item No 463117 Product of Greentek Greentek reserves the rights to modify a product without prior notice whether in price design color or codes in order to offer...

Страница 2: ...icated Electric Receptacle 8 8 Outside Fresh Air and Stale Air Hoods 8 9 The matrix High Performance Ventilation Hood 9 10 Benefits of the Duotrol System 9 11 Balancing the unit 10 12 Controls Connect...

Страница 3: ...CFM L S CFM REQUIRED Master Bedroom x 20 cfm 10 L s With Basement x 20 cfm 10 L s Single Bedroom x 10 cfm 5 L s Living Room x 10 cfm 5 L s Dinning Room x 10 cfm 5 L s Family Room x 10 cfm 5 L s Recre...

Страница 4: ...t length 35 ft 10 7 m Round plastic diffuser equivalent length 100 ft 30 5 m NOTE Maximum airflow assumes diffuser is in full open position Tee take off equivalent length 50 ft 15 24 m Angle boot equi...

Страница 5: ...or the forced air system s manufacturer The HRV and forced air system must be in continuous mode to achieve maximum comfort and to avoid cross contamination NOTE TO INSTALLER Dwellings with multiple...

Страница 6: ...tems requires one HRV ERV per system Insure the unit runs in conjunction with forced air system Ref wiring diagram for furnace interlock For minimum distance between return and forced air system check...

Страница 7: ...and seal with a Tie wrap figure 5 2 Insert insulation inside the double collar figure 5 3 Finish by taping the vapor barrier to the collar to insure proper seal Once insulated flex is attached to the...

Страница 8: ...icated receptacle with 115v It is not recommended to connect unit with an extension cord If no receptacle is available please call an electrical contractor and have one installed Insure polarized is c...

Страница 9: ...outside AIRFLOW INSTALLATION IMPORTANT Install ventilation hood a minimum of 18 457mm above grade Do not install under a deck enclose porch patio garages crawl spaces or attics WARNING Insure the ven...

Страница 10: ...177 84 180 85 0 54 135 172 81 176 83 0 52 130 167 79 173 82 0 50 125 162 76 169 80 0 48 120 157 74 165 78 0 46 115 152 72 161 76 0 44 110 146 69 156 74 0 42 105 141 67 152 72 0 40 100 136 64 147 69 0...

Страница 11: ...the HIGH LOW balancing pressure taps on the fresh air side located on the HRV ERV access door Ref Fig 11 4 Adjust the fresh airflow integrated balancing damper adjustment screw clockwise until you re...

Страница 12: ...B G INTERLOCK TIMER MINUTERIE R B B1 W G CONTROL COMMANDE R COM NC NO B G INTERLOCK TIMER MINUTERIE R B B1 W G CONTROL COMMANDE R COM NC NO B G INTERLOCK TIMER MINUTERIE R B B1 W G CONTROL COMMANDE R...

Страница 13: ...Controller Y W R G Y W R G Thermostat B INTERLOCK COM N O N C RLY1 4 3 2 1 D1 SW3 TIMER REMOTE W B1 G R G B R MASTER PROG J2 C Y W R G B INTERLOCK COM N O N C RLY1 4 3 2 1 D1 SW3 TIMER REMOTE W B1 G...

Страница 14: ...ll bracket is used for hanging the units Verify that flexible duct connections are use between the HRV or ERV and the rigid duct Verify that the motors are operating and are not obscured by any debris...

Страница 15: ...it as required consult your owner s manual for instructions on inspecting and cleaning the core A build up of dust and dirt can restrict airflow and reduce the efficiency of your HRV ERV After inspect...

Страница 16: ...air LOW BAS LOW BAS LOW BAS LOW BAS HIGH HAUT HIGH HAUT HIGH HAUT HIGH HAUT Pressure Pression Fresh air Air frais Stale air Air vici IN W G Pascal CFM L s CFM L s PO d eau Pa PCM PCM 0 50 125 161 76...

Отзывы: