IMPORTANT - PLEASE READ MANUAL BEFORE INSTALLATION
CONTENTS
TO REDUCE OR AVOID THE HAZARDS OF ELECTRIC SHOCK AND FIRE:
CAUTIONS CONCERNING THE OPERATION AND FULL EFFICIENCY OF THIS PRODUCT:
CAUTION:
Do not install in a cooking area or connect directly to any appliance. Turn off all integral disconnects before servicing.
NOTICE:
Prior to installing, serious consideration must be taken to insure this ventilation system will operate properly if integrated to any other type of
mechanical system, i.e. a forced air system, or an air handling unit. To insure proper operation & compatibilities of both system, it is required that the airflow’s of
the Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV) be balanced, by following the procedures found in this manual.
The way that your Heat/Energy-recovery ventilator is installed may make a significant difference to the electrical energy that you will use. To minimize the
electricity use of the Heat/Energy-recovery ventilator, a stand-alone fully ducted installation is recommended. If you choose a simplified installation that operates
your furnace airhandler for room-to-room ventilation, an electrically efficient furnace that has an electronically commutated (EC) variable speed blower motor will
minimize your electrical energy consumption and operating cost.
LIMITATIONS:
The product is for residential applications only. Must be installed in accordance with all national and local regulations, building and safety codes.
SECTION
PAGE
1. Ventilation requirements . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Fitting equivalent lengths . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. Types of Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. Installation of the HRV / ERV . . . . . . . . . . . . . . . . . . . . . . . 7
5. Insulated Flex from Unit to Outside Wall . . . . . . . . . . . . . . . . . 7
6. Condensation Drain Line . . . . . . . . . . . . . . . . . . . . . . . . . 8
7. Dedicated Electric Receptacle . . . . . . . . . . . . . . . . . . . . . . 8
8. Outside Fresh Air and Stale Air Hoods . . . . . . . . . . . . . . . . . . 8
9. The matrix™ High Performance Ventilation Hood . . . . . . . . . . . . 9
10. Benefits of the Duotrol™ System . . . . . . . . . . . . . . . . . . . . 9
11. Balancing the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
12. Controls Connection. . . . . . . . . . . . . . . . . . . . . . . . . . .12
13. Wiring Diagrams for furnace interlock systems . . . . . . . . . . . . .13
14. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
15. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
16. Balancing Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
• Before servicing or cleaning the HRV system, always remove the power cord
from the AC wall outlet.
• To reduce the hazards of electric shock or fire, do not perform any service
to the HRV system other than those stated in the operating manual
instructions.
• To reduce the risk of electric shock, this ventilation system (HRV/ERV)
comes equipped with a 3-prong plug-in. This plug will fit in a polarized outlet
only one way.
• Do not use ventilation system for outdoor application.
• Do not pull or twist power cord when disconnecting it from the ventilation
system. Grasp the plug firmly, not the cord.
• Do not modify the power plug in any way; if modified, risk of electric shock
fire or even damage to the unit may occur.
• Do not use the ventilation system for removal of flammable fumes, gases or
connect directly to any appliances.
• Use a dedicated AC 120V outlet only.
• Do not obstruct or cover the air intake or air outlet of the ventilation system.
• Do not modify, repair or disassemble this system. These tasks are to be
performed by authorized serviced personnel only. Fire, electrical shock and/
or bodily injury may occur if these warnings are not followed.
• To prevent injuries, do not operate the ventilation system, while servicing
or maintaining. There are impeller wheels turning at a very high speed that
must fully stop rotating prior to accessing the inside of the unit.
• Always assess the operation of the ventilation system on how it may
interact with vented combustion equipment (ie. Gas Furnace, Oil Furnace,
Combustion, Appliances, etc.)
• Do not use for swimming pool/spa applications.