GreenTech pureAir 750 Plus Скачать руководство пользователя страница 7

7

ARC® Cell Replacement

1.  Disconnect unit from power source. 

2.  Remove the Cover’s two screws along the 

top edge with a #1 Phillips-Head screw 

driver. 

3.  Tilt the Cover away from the top of the unit. 

4.  Remove the Black Grille by sliding it out. 

5.  Locate the ARC Cell and gently lift it up out 

of the case. 

6.  Disconnect the power cable to your old 

ARC Cell and replace it with your new 

ARC Cell. Ensure plug is fully seated in the 

connection and the wire is fully seated into 

the grommet/bulkhead. 

7.  Place the ARC Cell in place in the unit with 

the warning label visible, making sure air 

can flow through the cell. 

8.  Replace the Black Grille. 

9.  Close and secure the Cover of the unit. 

10.  Reconnect unit to power source.

WARNING: Make sure to disconnect the unit from its power source 
before any maintenance or cleaning is done.

WARNING: Please do not throw a used ARC

®

 Cell in the garbage. See 

CELL DISPOSAL (PG. 9) for disposal instructions

Your ARC Cell should be replaced every year.

See Page 9 for Replacement Part Numbers.

STEP 

2-3, 9

STEP 6

STEP 5&7

Содержание pureAir 750 Plus

Страница 1: ...Owner s Manual Active Air Purification with ARC Technology...

Страница 2: ...drogen peroxide The Active Radiant Catalysis purification process uses ultraviolet energy to activate a multi metal catalyst which converts water vapor into oxidizers including peroxide and hydroxyls...

Страница 3: ...ment humidity and temperature Warnings Please read and follow all warnings and cautions before installing and using your unit Use this unit only in a manner intended by the manufacturer If you have qu...

Страница 4: ...Diagrams Unit Front Unit Rear Unit Cover Air Outlet DC Power Jack DC Power Plug Unit Bottom Unit Internals Air Intake ODOGard MERV Filter ARC Cell Power Compartment Bipolar Ionization Module Mounting...

Страница 5: ...y the angled grille should be pointed upward and mounted as high on the wall as practical within 18 inches of the ceiling if possible 2 Plug the power adapter s elbow style DC connector into the unit...

Страница 6: ...away from the top of the unit 4 Replace the used Filter at the bottom with the red side out 5 Close and secure the Cover of the unit 6 Reconnect unit to power source WARNING Make sure to disconnect th...

Страница 7: ...n the connection and the wire is fully seated into the grommet bulkhead 7 Place the ARC Cell in place in the unit with the warning label visible making sure air can flow through the cell 8 Replace the...

Страница 8: ...y sliding it out 5 Disconnect BPI Module s black and white wires from lever connectors orange clear 6 Remove screws securing the BPI Module to the unit and remove Module 7 Install new BPI Module secur...

Страница 9: ...the spent ARC Cell and UV Lamp at your local recycling center or by local regulations Replacements Part Numbers Please reference these part name and numbers when contacting your dealer or Greentech fo...

Страница 10: ...Fan needs replaced Contact your dealer or visit our website greentechenv com to contact us directly Check for secure electrical connections Check the Line Fuse Try another ARC Cell Ballast needs repla...

Страница 11: ...visit us online at greentechenv com Before any product is sent for service the customer should contact the Greentech Service Center to obtain a Return Merchandise Authorization RMA Number This RMA Nu...

Страница 12: ...OM REVISION Greentech pureAir 750 Plus WallMount Owners Manual 211214 greentechenv com...

Отзывы: