2

About pureAir 750+ Wall Mount

This unit is designed to be permanently mounted to a wall to help reduce 
odors and create a fresh, clean environment. pureAir 750+ Wall Mount 
is perfect for providing air purification in large rooms, small offices, or 
similar spaces without ductwork, up to 750 sq. ft.

pureAir 750+ Wall Mount utilizes Active Radiant Catalysis (ARC

®

technology that generates advanced oxidation products (AOPs), primarily 
consisting of hydro-peroxides, or safe, vaporized hydrogen peroxide. The 
Active Radiant Catalysis purification process uses ultraviolet energy to 
activate a multi-metal catalyst, which converts water vapor into oxidizers 
including peroxide and hydroxyls. In addition to the ARC process, Bipolar 
Ionization and the unique ODOGard® treated filter are used to assist in 
neutralizing pollutants and odors.

Table of Contents

Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unit Diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cleaning the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Filter Replacement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ARC Cell Replacement   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
BPI Module Replacement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Replacement Part Numbers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cell Disposal  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Warranty Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Read all instructions carefully in user manual before operating air purifier.

Содержание pureAir 750 Plus

Страница 1: ...Owner s Manual Active Air Purification with ARC Technology...

Страница 2: ...drogen peroxide The Active Radiant Catalysis purification process uses ultraviolet energy to activate a multi metal catalyst which converts water vapor into oxidizers including peroxide and hydroxyls...

Страница 3: ...ment humidity and temperature Warnings Please read and follow all warnings and cautions before installing and using your unit Use this unit only in a manner intended by the manufacturer If you have qu...

Страница 4: ...Diagrams Unit Front Unit Rear Unit Cover Air Outlet DC Power Jack DC Power Plug Unit Bottom Unit Internals Air Intake ODOGard MERV Filter ARC Cell Power Compartment Bipolar Ionization Module Mounting...

Страница 5: ...y the angled grille should be pointed upward and mounted as high on the wall as practical within 18 inches of the ceiling if possible 2 Plug the power adapter s elbow style DC connector into the unit...

Страница 6: ...away from the top of the unit 4 Replace the used Filter at the bottom with the red side out 5 Close and secure the Cover of the unit 6 Reconnect unit to power source WARNING Make sure to disconnect th...

Страница 7: ...n the connection and the wire is fully seated into the grommet bulkhead 7 Place the ARC Cell in place in the unit with the warning label visible making sure air can flow through the cell 8 Replace the...

Страница 8: ...y sliding it out 5 Disconnect BPI Module s black and white wires from lever connectors orange clear 6 Remove screws securing the BPI Module to the unit and remove Module 7 Install new BPI Module secur...

Страница 9: ...the spent ARC Cell and UV Lamp at your local recycling center or by local regulations Replacements Part Numbers Please reference these part name and numbers when contacting your dealer or Greentech fo...

Страница 10: ...Fan needs replaced Contact your dealer or visit our website greentechenv com to contact us directly Check for secure electrical connections Check the Line Fuse Try another ARC Cell Ballast needs repla...

Страница 11: ...visit us online at greentechenv com Before any product is sent for service the customer should contact the Greentech Service Center to obtain a Return Merchandise Authorization RMA Number This RMA Nu...

Страница 12: ...OM REVISION Greentech pureAir 750 Plus WallMount Owners Manual 211214 greentechenv com...

Отзывы: