EK628 Battery-powered Crimping Tool
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
9
Problem
Probable Cause
Probable Remedy
Tool is inoperative.
Dirt, contaminants, etc., in ram area
of tool.
Clean tool.
Crimping tool battery contacts
damaged.
Reform contacts.
Tool components worn or damaged.
Return tool to an authorized
Greenlee service center.
Dies stop during operation.
Oil level is low.
Return tool to an authorized
Greenlee service center.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Hold for approxi-
mately 10 seconds
LED display glows for
20 seconds.
Battery charge low.
Charge or replace battery.
Tool loses oil.
Damaged internal seal.
Return tool to an authorized
Greenlee service center.
Maintenance
Each Operating Day
Before use:
1. Inspect dies for wear or damage such as cracks,
gouges, or chips.
2. Inspect the tool for damage or leaks. If damage is
detected, return the tool to an authorized Greenlee
service center for inspection.
Skin injection hazard:
Do not use hands to check for
oil leaks. High pressure oil easily
punctures skin causing serious
injury, gangrene, or death. If injured,
seek medical help immediately to
remove oil.
After use:
1. Wipe all tool surfaces clean with a damp cloth and
mild detergent.
Do not use solvents or flammable
liquids to clean the crimping tool.
Solvents or flammable liquids could
ignite and cause serious injury or
property damage.
2. Fully retract the ram. Place the tool in the carrying
case. Store in a cool, dry place.
3. Charge the battery.
Monthly
1. Thoroughly clean all surfaces.
2. Oil the pin joints.
Annually or After 10,000 Crimps
Return the tool to an authorized Greenlee service
center for inspection.
Troubleshooting
Before You Begin
1. Make sure that the battery is charged. Recheck
the battery after several minutes to make sure the
battery is holding its charge.
2. Use a
nonflammable
contact cleaner or pencil
eraser to clean the electrical contacts on the
battery and crimping tool.
3. Reinstall the battery and check the tool again.