910FS Splicer
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
38
Section 4. Specifications
Applicable Fibers
SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653),
NZDS/LEAF (ITU-T G.655), BIF (ITU-T G.657)
Fiber Cleaved Length
10 mm
Cladding Diameter
80-150 μm
Coating Diameter
100-1000 μm
Fiber Count
Single
Fiber Aligning Method
Auto Core alignment
Return Loss
≥60 dB
Actual Average Splice Loss
0.02 dB (SM), 0.01 dB (MM),
0.04 dB (DS), 0.04 dB (NZDS, LEAF, and BIF)*
Splicing Mode
60 preset/user-definable modes
Splicing Time
9 seconds in standard SM, 12 seconds in AUTO modes
Arc Calibration Mode
Automatic and Manual
Protection Sleeve Length
60 mm, 40 mm and micro sleeves
Storage of Splice Results
5000 results
Tension Test
2 N
Fiber Display Magnification
240X
Tube Heating Mode
20 preset and user definable modes;
adjustable 0–240 seconds
Attenuator Mode
0.1 to 15 dB
Electrode Life
3000 splices
Splices per Battery Charge
360
Tube Heating Time
36 seconds typical
Splicing/Heating Times
250 cycles (splice/tube heat) typical
Display
5.7 inch color turn-over LCD
Connectivity
RS-232/USB 2.0
Ingress Protection
IP5X
Drop Test
80cm onto bottom axis
Operating Condition
0-5000 m (0-16,400 ft) above sea level; 0 to 95% RH;
-10 to 50 °C (14 to 122 °F): Maximum wind velocity of
15 m/s
Storage Condition
-20 to 70 °C (-4 to 158 °F); 0 to 95% RH
Power Supply
North America AC adapter (100-240 VAC);
Li battery (6600 mAh)
Weight
2.6 kg (5.72 lb) including battery
Dimensions (HxWxT)
180x160x155 mm (7.1 x 6.3 x 6.1 in)
Splice-on Connector
SC, LC, FC, and ST
* Insertion loss is for cut and re-splice of identical fibers.