background image

Centrifugal, Industrial and Filtered Supply

3

To ensure a successful installation, the instructions in 
this manual should be read and adhered to. Failure to 
comply with proper installation procedures may void the 
warranty.

Unit and System Identification Tags

Each fan has a permanently affixed manufacturer’s 
engraved metal nameplate containing the model 
number and individual serial number.

The tag shown is an example of an identification 
nameplate on the fan. The information provides general 
details about the fan, 
as well as contains 
specific information 
unique to the unit. 
When contacting your 
local manufacturer’s 
representative with 
future needs or questions, have the information on this 
label available. Tags are mounted in an area which is 
clearly visible, usually on the side of the fan cabinet.

Pre-Installation Information

Before installation, it is important to be certain the 
mounting surface will bear the operating weight of the 
unit. For proper unit operation, it is also important that it 
be operated in a completely level position.

For further details on safety practices involving 
industrial and commercial fans, please refer to AMCA 
Publication 410.

Electrical Disconnects

All fan motors should have disconnects located in close 
visual proximity to turn off electrical service. Service 
disconnects shall be locked-out when maintenance is 
being performed.

Moving Parts

All moving parts must have guards to protect personnel. 
Refer to local codes for requirements as to the number, 
type and design. Fully secure fan wheel before 
performing any maintenance. The fan wheel may start 
“free wheeling” even if all electrical power has been 
disconnected. Before the initial start-up or any restart, 
check the following items to make sure that they are 
installed and secure.

•  Do not spin fan wheel faster than the maximum 

cataloged fan RPM.

•  Adjustments to fan speed significantly affects motor 

load. If the fan RPM is changed, the motor current 
should be checked to make sure it is not exceeding 
the motor nameplate amps.

General Information

Table of Contents

General Safety Information . . . . . . . . . . . . . . . . . . . . 1

 Receiving / Unpacking / Handling / Storage   . . . . . . 2
 Inspection and Maintenance during Storage . . . . . 2
Removing from Storage . . . . . . . . . . . . . . . . . . . . . 3

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Unit and System Identification Tags  . . . . . . . . . . . 3
Pre-Installation Information . . . . . . . . . . . . . . . . . . 3
Electrical Disconnects . . . . . . . . . . . . . . . . . . . . . . 3
Moving Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Guards / Access  Doors . . . . . . . . . . . . . . . . . . . . . . 4
Air Pressure and Suction . . . . . . . . . . . . . . . . . . . . 4

Fans - Rigging and Lifting . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Ducted Inlet Installations . . . . . . . . . . . . . . . . . . . . 5
Ducted Outlet Installations . . . . . . . . . . . . . . . . . . . 5
Non-Ducted Installations . . . . . . . . . . . . . . . . . . . . 5
Fan Drainage Piping and Trap Detail . . . . . . . . . . . 6
 Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Belt Guards  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Electrical Connections  . . . . . . . . . . . . . . . . . . . . . . . 7
Radial Gap, Overlap and Wheel Alignment  . . . . . . . 8
Unit Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Visual Inspection of Equipment . . . . . . . . . . . . . . . 9
Additional Steps for Initial Start-Up . . . . . . . . . . . . 9

Vibration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Routine Maintenance  . . . . . . . . . . . . . . . . . . . . . . . 10

 Motors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
 Shaft Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
 Belt Drive Maintenance . . . . . . . . . . . . . . . . . . . . 11
Belt Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Variable Frequency Drive Operation . . . . . . . . . . . . 12
Field Coating Touch-Up Procedure . . . . . . . . . . . . . 12
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Maintenance Log . . . . . . . . . . . . . . . . . . . . . Backcover
Our Commitment . . . . . . . . . . . . . . . . . . . . . Backcover

Removing from Storage

As fans are removed from storage to be installed in their 
final location, they should be protected and maintained 
in a similar fashion until the fan equipment goes into 
operation.

Prior to assembly and installation of the unit and system 
components, inspect the fan assembly to make sure it is 
in working order.

1.  Check all fasteners, set screws on the fan, wheel, 

bearings, drive, motor base and accessories for 
tightness.

2.  Rotate the fan wheel by hand and assure no parts 

are rubbing. Access to the wheel is obtained 
through a bolted panel located on the side of the 
fan housing.

3.  Ensure proper wheel settings for radial gap and 

alignment. Refer to Radial Gap, Overlap and Wheel 
Alignment section on page 8.

Содержание AFDW

Страница 1: ...ore moving forward 1 Follow all local electrical and safety codes as well as the National Electrical Code NEC the National Fire Protection Agency NFPA where applicable Follow the Canadian Electric Cod...

Страница 2: ...he surfaces Wipe clean thoroughly with Tectyl 506 Ashland Inc or the equivalent For hard to reach internal surfaces or for occasional use consider using Tectyl 511M Rust Preventive or WD 40 or the equ...

Страница 3: ...alled and secure Do not spin fan wheel faster than the maximum cataloged fan RPM Adjustments to fan speed signi cantly affects motor load If the fan RPM is changed the motor current should be checked...

Страница 4: ...rs are recommended to prevent damage to the unit Failure to use spreader bars may result in damage which becomes the installer s responsibility Guards Motor Cover Weatherhood Shaft Belt Inlet or Outle...

Страница 5: ...cted Inlet Installations Inlet Duct Turns Installation of a duct turn or elbow too close to the fan inlet reduces fan performance because air is loaded unevenly into the fan wheel To achieve full fan...

Страница 6: ...ding vibration isolators should be used The fan is mounted directly on the isolation base and must be supported for the entire length of the fan base angle Refer to the Centrifugal Fan Isolation Base...

Страница 7: ...ment points for belt guard mounting bracket locations These locations vary with motor mounting position arrangement and fan type The bearing supports and fan structure are used in most instances and w...

Страница 8: ...bolts and centering the wheel is acceptable as a secondary option Overlap or offset is adjusted by loosening the wheel hub from the shaft and moving the wheel to the desired position along the shaft...

Страница 9: ...tructural and or component failure Many of these conditions can be discovered by careful observation Refer to the troubleshooting section of this manual for corrective actions If observation cannot lo...

Страница 10: ...s Bearings are the most critical moving part of the fan therefore special care is required when mounting them on the unit and maintaining them Refer to the following chart and the manufacturers instru...

Страница 11: ...Application Guide FA 127 11 Measuring Belt Tension found online at greenheck com in the Resources section Check belt tension before start up and after the rst 24 hours of operation The belt tension sh...

Страница 12: ...data sheet Four disposable foam brushes One sheet sandpaper Repair procedure details NOTE While the manufacturer provides heavy duty quality products for marine environments routine paint touch ups ma...

Страница 13: ...CAUTION A fan manufactured with an explosion resistant motor does not certify the entire unit to be explosion proof Refer to UL Listing Mark for the fans approved usage Each fan bears a manufacturer...

Страница 14: ...nd Filtered Supply 14 Industrial Process Heat Slinger Weatherhood Arrangement 10 only Volume Control Damper Outlet Companion Flange Outlet Flange Inlet Flange Inlet Companion Flange Shaft Bearings Bel...

Страница 15: ...d or new lters are ready to be installed place the lters back into the racks in the reverse order of which they were removed When all lters are in place close and secure the top roof panels High Horse...

Страница 16: ..._____Time _____________ AM PM Notes ___________________________________________ _________________________________________________ _________________________________________________ ____________________...

Отзывы: