Trendy Series
Troubleshooting
Breaker trippe
or fuse burnt out
When the breaker is set ON, it will
trip at once
When the unit is turned on, the
breaker will trip in a few minutes
Measure the insulating resistance
for grounding to confirm whether
there is electrical leakage or short
circuit in the unit
Insulation malfunction of line or componen
in the air conditioner. Insulation breakdow
occurs after radiation, which causes shor
circuit or electricity leakage. Measure
insulating resistance or use one-by-on
elimination method;
Malfunction of fuse. Replace it.
Air
conditioner
does not response
after powered on.
(The buzzer does
not sound after the
plug is connected
and the unit does
not response after
the
remote
controller is used
to turn it on)
No power supply
Check power supply circuit
The power plug is not or poorly
connected
Check and plug well plug, make
loosen contact firm
Controller fuse is burnt out
Change control fuse
Loose or poor contact of transformer
connection, or transformer malfunction
Secure the wire connection: measure
the output voltage of the transformer
and replace it if the value is wrong
The controller is broken
Replace the controller
Batteries of remote controller are low
Change battery
Malfunction of remote controller
Loose or poor connection of receiving
head
Receiving head is broken
First press the "AUTO" button of the
manual switch. If there is no response,
check according to the above method;
if it is normal after the button is
pressed, check if the installation
location and wire connection of the
receiving head are correct. If correct,
replace the receiving head, or the
remote controller.
Remote
controller does
not receive signal
(When powered
on, the buzzer
will send out a
sound, unless it is
broken)
Air conditioner cannot start up
Trouble shooting 1
Analysis in this section is used for Linge Wind D.C. Variable Frequency Series. Before analysis, you can diagnose
according to the code displayed on indoor unit or indicator display on outdoor unit. (Refer to Malfunction
display section).
Содержание Trendy Series
Страница 1: ...1 115V R410A CANCEL Model Remarks Summary and features Trendy Series ...
Страница 4: ...3 Window receiver Part name Indoor Unit Outdoor Unit ...
Страница 6: ...UOverall and Installing Dimension of Outdoor Unit Unit mm Bolt Nut Wrench ...
Страница 19: ...8 Trendy Series Exploded View and Components and Parts List Exploded View of Indoor Unit ...
Страница 21: ...Trendy Series Exploded View of Components and Parts of Indoor Unit ...
Страница 23: ...Trendy Series Exploded View of Outdoor Unit ...