Operation procedures/pictures
Disassembling the electric box
Screw off the two pieces of screws that fix the electric
box and unloose the clasp. Pull out the tube sensor,
unloose the grounding nut and unplug the motor
connecting terminal take out the electric box.
Disassembling the evaporator assy
Screw off the screws that fix the evaporator, one piece
on the left and two pieces on the right.
Lift the left end of the evaporator slightly upward with
your end and push it rearward to let out the side clasps
of the evaporator from the groove. Take out the
evaporator carefully and pay attention to protecting the
connecting pipe.
Screws
Screws
Disassembling the motor
Screw off the 3 pieces of screws that fix the motor
clamp to take off the motor clamp.
Screw off the fixing nut that fixes the cross flow fan to
pull out the motor from the cross flow fan.
Screws
Right motor
clamp
Disassembling the cross flow fan
Refer to the above steps to take out the cross flow fan
from the base plate after taking out the motor.
screws
motor
cross flow fan
Tube sensor
Screws
Grounding nut
Motor connecting
terminal
Содержание Trendy Series
Страница 1: ...1 115V R410A CANCEL Model Remarks Summary and features Trendy Series ...
Страница 4: ...3 Window receiver Part name Indoor Unit Outdoor Unit ...
Страница 6: ...UOverall and Installing Dimension of Outdoor Unit Unit mm Bolt Nut Wrench ...
Страница 19: ...8 Trendy Series Exploded View and Components and Parts List Exploded View of Indoor Unit ...
Страница 21: ...Trendy Series Exploded View of Components and Parts of Indoor Unit ...
Страница 23: ...Trendy Series Exploded View of Outdoor Unit ...