Operating Procedures / Photos
Disassemble valves
Unscrew the two screws fixing the big valve,
unsolder the soldering point between the big
valve and the return-air duct and remove the big
valve.
(Note: when unsoldering the soldering point, use
wet cloth to completely wrap the big valve to
prevent valve body from being harmed by high
temperature.)
Unscrew the two screws fixing the small valve,
unsolder the soldering point connecting the small
valve and the fork type pipe, and remove the small
valve.
bolts
Disassemble Compressor
Unscrew the three nuts with washers at the foot of
the compressor. Unsolder the soldering points at
the suction and the discharge pipes of the compressor,
carefully remove the pipes and take out the compressor.
compressor bolt
big valve
small valve
Содержание Trendy Series