10
Outdoor Units_Heat Recovery
Ton
12
14
16
Model
-
GMV-Q144WM/B-F(U)
GMV-Q168WM/B-F(U)
GMV-Q192WM/B-F(U)
Module combination
-
GMV-Q72WM/B-F(U)+
GMV-Q72WM/B-F(U)
GMV-Q72WM/B-F(U)+
GMV-Q96WM/B-F(U)
GMV-Q96WM/B-F(U)+
GMV-Q96WM/B-F(U)
Performance
Nominal Cooling
Capacity
Btu/h
144000
168000
192000
kW
42.2
49.1
56.3
Rated Cooling
Capacity
Btu/h
134000
157000
180000
Nominal Heating
Capacity
Btu/h
162000
189000
216000
kW
47.5
55.4
63.3
Rated Heating
Capacity
Btu/h
150000
175000
200000
Cooling Power Input
kW
5.45+5.45
5.45+7.3
7.3+7.3
Heating Power Input
kW
5.80+5.80
5.80+7.85
7.85+7.85
Sound Pressure Level
dB(A)
-
-
-
Power Supply
-
208/230V 3~ 60Hz
Compressor
Type
-
Inverter scroll type
Inverter scroll type
Inverter scroll type
Number
N
1+1
1+1
1+1
Motor Output
①
kW
-
-
-
Starting Method
-
Inverter
Inverter
Inverter
Operating Range
-
-
-
-
Refrigeration Oil
Brand
-
FVC68D or FV-68H
FVC68D or FV-68H
FVC68D or FV-68H
Fan
Type × Quantity
-
Propeller×(2+2)
Propeller×(2+2)
Propeller×(2+2)
Motor output
W
750×2+750×2
750×2+750×2
750×2+750×2
Starting method
-
Inverter
Inverter
Inverter
Air flow rate
m
3
/h
14000+14000
14000+14000
14000+14000
cfm
8240+8240
8240+8240
8240+8240
Max. external static
pressure
Pa
82
82
82
in.W.G
0.328
0.328
0.328
Ambient
temperature
range
Cooling
°C
-5~52
-5~52
-5~52
℉
23~125.6
23~125.6
23~125.6
Heating
°C
-20~24
-20~24
-20~24
℉
-4~75.2
-4~75.2
-4~75.2
Refrigerant
Refrigerant Type
-
R410A
R410A
R410A
Refrigerant Charge
Volume
kg
9.6+9.6
9.6+11.2
11.2+11.2
lbs.
21.16+21.16
21.16+24.69
24.69+24.69
Control
-
EXV
EXV
EXV
Pipe
Connection
Low pressure Gas
Pipe Size
mm
28.6
28.6
28.6
in.
1 1/8
1 1/8
1 1/8
High pressure gas
pipe
mm
Φ
22.2
Φ
22.2
28.6
in.
7/8
7/8
1 1/8
Liquid Pipe Size
mm
12.7
15.9
15.9
in.
1/2
5/8
5/8