background image

Clean and maintenance

 

■ 

2.

 

■ 

2.

4.

WARNING

WARNING

Please contact qualified professionals for

service.

Do not remove the panel when cleaning it.

■ 

■ 

■ 

■ 

■ 

Clean filter

1. Open panel

Pull out the panel

to a certain angle

as shown in the fig.

Remove filter

 

Remove the filter as

indicated in the fig.

Error Code

Error code

3.


F2

NOTE

Troubleshooting

C5

F0

F1

H6

U8

Install filter

Install the filter and then close the panel cover

tightly. 

E

8

E5

E6

Notice for recovery

1.

Clean filter

Use dust catcher or water to clean the filter.

If there're other error codes, please contact  qu-

alified professionals for service.

Clean surface of indoor unit

When the surface of indoor unit is dirty, it is recomm-

ended to use a soft dry cloth or wet cloth to wipe it. 

1

4

Many packing materials are recyclable mate-

The filter should be cleaned every three months .

If  there is much dust in the operation environme-

After removing the filter, do not touch fins to 

avoid injury.

Do not use fire or hair dryer to dry the filter to 

avoid deformation or fire hazard.

When air conditioner status is abnormal, tempe-

rature indicator on indoor unit will blink to display

corresponding error code. Please refer to below 

list for identification of error code. 

t

a

ir

p

o

r

p

p

a

 

n

m

e

h

e

s

o

p

s

i

d

 

e

s

a

e

l

P

 .

s

l

a

ir

recycling unit.

e

s

a

e

l

p

  ,

r

e

n

o

it

i

d

n

o

c

 r

i

a

 

e

h

e

s

o

p

s

i

d

 

o

t

n

a

w

 

u

o

y

 f

I

for the correct disposal method.

Turn off the air conditioner and disconnect the 

power before cleaning the air conditioner to av-

oid electric shock.

Do not wash the air conditioner with water to 

avoid electric shock.

Do not use volatile liquid to clean the air 

conditioner.

Do not use liquid or corrosive detergent to clean 

the appliance and do not splash water or other 

liquid onto it , otherwise, it may damage the 

plastic components , even cause electric shock.

nt, clean frequency can be increased.

contact local dealer or consultant service center

When the filter is very dirty, use the water 

(below 45

) to clean it , and then put it in a 

shady and cool place to dry.

It can be eliminated after restarting the unit.

If not, please contact qualified professionals

for service.

NOTICE

NOTICE:

 Checking after use-season

Check whether air inlets and air outlets are bl-

3.

4.

1.

2.

1.

3.

NOTICE: 

Checking before use-season

2.

Disconnect power supply.

Clean filter and indoor unit’s panel.

   ocked.

Check whether air switch, plug and socket  are

Check whether mounting bracket for outdo or

unit is damaged or corroded. If yes, please

contact dealer.

5.Check whether drainage pipe is damaged.

 in good condition.

Check whether filter is clean.

Check whether mounting bracket for outdoor

unit is damaged or corroded . If yes, please

contact dealer.

Содержание Livo Gen 3

Страница 1: ...HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM OWNER S MANUAL TWD 1594 Livo owners printer qxp_Layout 1 2 21 17 2 10 PM Page 1...

Страница 2: ......

Страница 3: ...LIVV09HP115V1AH LIVV12HP115V1AH...

Страница 4: ...01 06 14 15 16 18 Parts name 21 22 OPERATION OF WIRELESS REMOTE CONTROLLER Clean and maintenance Checked items before maintenance Installation notice Installation of indoor unit Test and operation Co...

Страница 5: ...ymbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information used to indicate...

Страница 6: ...allation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications H...

Страница 7: ...20cm separation distance will be maintained between the device excluding its handset and users Cet appareil est conforme aux limites d exposition au rayonnement RF stipul es par la FCC et l IC pour un...

Страница 8: ...ir conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The groundi...

Страница 9: ...must be po sitioned so that the plug is accessible For the air conditioner with plug the plug should be re achable after finishing in stallation For the air conditioner with out plug a circuit breaker...

Страница 10: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Страница 11: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Страница 12: ...controller is lost or damaged please use aux button to turn on or turn off the air conditioner The operation in details is as below As shown in the figure open panel and press aux button to turn off...

Страница 13: ...ng in cooling mode with low fan speed 2 If the RoomTemperature is between 4 F higher than and 4 F less than the set temperature the system will cycle 6 minutes ON and 4 minutes OFF in cooling mode The...

Страница 14: ...ignal has been sent to the air conditioner Under off status set temperature and clock icon will be displayed on the display of remote controller If timer on timer off and light functions are set the c...

Страница 15: ...indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould Having set X FAN function on After turning off the unit by pressing ON OFF button indoor fa...

Страница 16: ...again to exit turbo function and icon will disappear button 6 Press or button once increase or decrease set temperature 1 1 F Holding or button 2s later set temperature on remote controller will chang...

Страница 17: ...r time will change quickly Release this button when reaching your required time Note Clock time adopts 24 hour mode The interval between two operations can t exceeds 5s Otherwise remote contro ller wi...

Страница 18: ...it Function introduction for combination buttons Energy saving function Under cooling mode press TEMP and CLOCK buttons simultaneously to start up or turn off energy saving function When energy saving...

Страница 19: ...nction will cancel sleep function Temperature display switchover function I FEEL Function Under OFF status press and MODE buttons simultaneously to switch temp erature display between and Press and MO...

Страница 20: ...r will automatically adjust the indoor temperature according to the detected tempera OPERATION OF WIRELESS REMOTE CONTROLLER CHANGING BATTERIES AND ADDITIONAL NOTES To change batteries slide cover off...

Страница 21: ...s o p s i d e s a e l P s l a i r recycling unit e s a e l p r e n o i t i d n o c r i a e h t e s o p s i d o t t n a w u o y f I for the correct disposal method Turn off the air conditioner and disc...

Страница 22: ...tion of panel or other parts due to the change of temp erature In order to prevent blowing out cold air indoor unit will be started after delaying for several minutes which is a normal phenomenon Chec...

Страница 23: ...accident 1 minute sure that the unit is running in cooling mode Then fully close the valve at high pressure side liquid valve About 30 40 seconds later fully close the valve at low pressure side gas v...

Страница 24: ...the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power socket 5...

Страница 25: ...es when opening the hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 18 The pipe can be led o...

Страница 26: ...reachable after finishing installation For the air conditioner without plug an air switch must be installed in the line The air switch should be all pole parting and the contact parting distance shoul...

Страница 27: ...e gap between pipes and wall hole with sealing gum Fix the wall pipe Check if the indoor unit is installed firmly and closed to the wall Bind up the connection pipe power cord and Remove the wire clip...

Страница 28: ...let and outlet It may cause insufficient cooling heating capacity It may cause malfunction or damage the parts The gas valve and liquid valve of connection pipe are open completely The dust and sundri...

Страница 29: ...ethod of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Basi...

Страница 30: ...unit is 18 0 F 46 1 115 F for heat pump unit is 20 4 F 46 1 115 F For some models Outdoor side DB WB F hard mold Maximum cooling 26 7 19 4 80 67 46 1 23 9 115 75 Maximum heating NOTE 26 7 80 23 9 18...

Страница 31: ......

Страница 32: ...COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective parts or replacement parts or new units 2 Product cleaning requir...