58
Installation and Maintenance
Service Manual
Procedure
Steps
10. Remove 4-way valve assy
11. Remove compressor
4-way valve assy
compressor
foot nuts
Unsolder the welding joints connecting the
4-way valve assy with capillary sub-assy,
compressor and condenser; remove the 4-way
valve.
Note:
Before unsoldering the welding joint, wrap
the 4-way valve with a wet cloth completely
to avoid damage to the valve caused by high
temperature.
Remove 3 foot nuts on compressor, and then
remove the compressor.
Note:
Protect the ports of discharge pipe and suction
pipe to avoid foreign objects to enter it.