5HPRYDO3URFHGXUH
Procedure
Steps
1
2
10. Remove solenoid coil
Remove the screw on the solenoid coil,
and then remove the solenoid coil.
11. Remove compressor
Unsolder the pipes (including the soldering
joint among the 4-way valve, the
compressor, the condenser, the gas valve
and the liquid valve) connected to the
compressor at first. (NOTE: Before
unsoldering the joints, discharge the
refrigerant completely
˅
Remove the 3 foot nuts fixing the
compressor with wrench, and then remove
the compressor.
screw
solenoid coil
4-way valve assy
nuts
compressor
gas valve
liquid valve