84
Installation and Maintenance
Service Manual
Procedure
Step
Remove the screws fixing motor clamp
and then remove the motor clamp.
Remove the screws at the connection
place of cross flow blade and motor; lift
the motor and cross flow blade upwards
to remove them.
Remove the bearing holder sub-assy.
Remove the screw fi xing step motor and
then remove the step motor.
Screws
Screw
Motor clamp
9. Remove motor and cross fl ow blade
Motor
Cross fl ow
Holder
sub-assy
Step motor
Screws
a