Fig.6
φ
5
5mm
φ
5
5mm
Ø
5
5
19
Install the rear panel
1.
Always mount the rear panel horizontally. As the water drainage pipe at the left, when
adjusting the rear panel, this
side should not be too high; the right side should be slightly high.
2.
Fix the rear panel on the selected
location.
3.
Be sure that the rear panel has
been fixed
firm
enough to withstand
the weight of an adult of 60kg,
furthermore, the weight should be
evenly shared by each screw.
Mark on the middle of it
Gradienter
Wall
Wall
Space to
the wall
150mm
above
Space to
the wall
150mm
above
Left
Right
(Rear piping hole)
(Rear piping hole)
Install the piping hole
1
.
Make the piping hole
(ф
55
)
in the wall at a slight downward
slant to the outdoor side. At Fig.6.
2
.
Insert the piping-hole sleeve into the hole to prevent the connection piping
and
wiring from being damaged when
passing through the hole.
Indoor
Outdoor
Wall pipe
Seal pad
Protection
sleeve pipe
Install the water drainage pipe
1.
For
well draining, the drain
pipe
should be
placed at a downward
slant.
Do not wrench or bend the drain
pipe
or flood
its end
by water.
2
.
3
.
When the long drainage
pipe
passing through
indoor, wrap
it with
insulation materials.
Wrenched
Bent
Flooded
Connect indoor and outdoor electric wires
n th
y;(Fig.6)
1
.
Open the front panel upwardly;(Fig.6)
2
.
Screw off the fixing screw of cover plate
and screw off cover
plate (As show in Fig. 7)
3
.
Put the power connection cable through the
back of
indoor unit wire hole and take it out.
4
.
Connect the wire according to figure 8,
connection should be done correspondingly
one by one according to the wire board mark .
5
.
Put the power connection cable the section,
that
with
sheath into wire groove, and cover
the cover plate, screw on the fixing screw,
tighten the connection wire.
6
.
Cover the front panel cover.
For
the cooling and heating unit, signal control
7
.
wire
can be passed through the connection of
connector and indoor
unit, and use the wire clip
that is under the
body case, tighten the signal
control wire (As show in Fig. 9)
Power
connection
wire
Wire terminal
cover plate
Fig.7
Fig. 9
Fig. 8
Power connection wire
Install indoor unit
Connector
Signal control
(4X0.75)