background image

Please read the following carefully before operating.

WARNING

When having a burning smell 

or smoke, please turn off the power 
supply and contact with the service

may be damaged, and may cause 

center .

If the abnormity still exists, the unit 

electric shock or fire.

Don't operate the air conditioner

with wet hands.

Otherwise, it can cause an electric 
shock or fire.

Never cut off or damage power 

cables and control wires. If the power
cable and signal control wire were  

damaged, change them by professional 

Power must adopts the special 

circuit to prevent fire.

Otherwise, it can cause an electric
shock or fire.

Be sure to pull out the power 

plug as the air conditioner not in use
for a long time.

Otherwise, the accumulated dusts  

that may cause overheating or fire.

Never damage the electric wire 

or use the electric wire, which is not 

appointed.

Otherwise, it will cause overheating 

or fire. 

When cleaning, it is necessary 

to stop driving and turn off the power 

supply.

Cut off power supply 

Otherwise, it may cause electric 

shock or damage.

Rated voltage of this air cond-

itioner 230V, with a tolerable fluctu-

 

ation at          The compressor

will vibrate sharply if the voltage is 

too low, resulting in damage to
refrigerating system. Electrical
elements are easy to damage
if the voltage is too high. 

The power supply must adopt 

 the special circuit that with air switch

protection and assure it has enough 

 capacity. The unit will be turned on

 or off according to your requirement

  automatically, please do not turn on 

 or turn off the unit frequently, othe-

rwise disadvantage effect may be 

 caused to the unit. 

Operation and maintenance-Notices for operation

±23V.

Содержание GWCN24 B9NK1BA

Страница 1: ...1BA OWNER S MANUAL Models Thank you for choosing GREE air conditioner for correct operation please read this owner s manual carefully before operating the unit and keep it carefully for consultation G...

Страница 2: ...ng Installation service Notices for installation Install indoor unit Install outdoor unit Test operation and check after installation Thank you for choosing this air conditioner please read this owner...

Страница 3: ...usts that may cause overheating or fire Never damage the electric wire or use the electric wire which is not appointed Otherwise it will cause overheating or fire When cleaning it is necessary to stop...

Страница 4: ...can cause fire or explosion It can decrease the air conditioning capacity or cause a malfunction It can decrease the air conditioning capacity Please note whether the install ed stand is firm enough...

Страница 5: ...er for other purposes such as drying clothes preserving foods etc Notices for use To adjust the airflow and direction appropriately At operating the louvers of air conditioner could be adjusted by pre...

Страница 6: ...bove parameters are tested according to GB T7725 2004 moreover the cooling capacity heating capacity noise index are tested before leaving factory The max input power are tested under the max cooling...

Страница 7: ...equipments Defrosting Whenoutdoortemperatureislowbutwithhighhumidity afteralongwhilerunning frostwillformonoutdoorunit thatwillaffecttheheatingeffect atthistime theautodefrostingfunctionwillact thehe...

Страница 8: ...s remote control Names and functions of each part Air in Air out Filter Guide louver Wall pipe Bind tape Receiving window Connectionwire Indicator Drainage pipe Front panel DRY SET TEMP RUN COOL HEAT...

Страница 9: ...perature will be changed quickly Thetemperaturesettingrangeis16 30 COOL HEAT COOL button HEAT button At operating pressing this button could enter into the COOL mode directly At operating pressing thi...

Страница 10: ...F At AUTO FAN or HEAT modes the BLOW function cannot be set and there is no BLOW displayed Pressing this button enter into SLEEP state or quit the SLEEP state After unit is turned off and cancel the S...

Страница 11: ...on may be not available for some units 4 Press TURBO button can realize the ON and OFF of TURBO function The above operation please refers to Page 7 Page 8 for details Introduction for special functio...

Страница 12: ...can cause the malfunction of the wireless remote control take them out and don t let the leakage liquid damage the wireless remote control The operation should be in its receiving range It should be...

Страница 13: ...into the slots along the direction of arrows cover and clasp the front panel As show in Fig 4 a b Fig 4 Along the arrowhead direction open an angle at both slots of front panel then pull the air filt...

Страница 14: ...stallationstandoftheoutdoor unitisdamagedornot Ifdamaged pleasecontactthedealer Maintain after use Turn main power off Clean the filter as well as indoor and outdoor units bodies Clear dust and obstru...

Страница 15: ...act with our authorized maintenance center There s unusual smell blowing from the outlet after operation is started Sound of water flow can be heard during the operation When unit is started when oper...

Страница 16: ...ert it Is it in its receiving range Or obstructed On Page 7 Check the voltage in wireless remote control batteries On Page 10 inside is charged otherwise replace the Whether the wireless remote contro...

Страница 17: ...r to avoid condensing water be vaporized again restrain temperature rising defrosting there is water flowing out or vapor be produced Indoor unit cannot deliver air If unit is running under the high h...

Страница 18: ...ter can be easily drained out and the place is easily connected for outdoor unit Select a location where children can not reach Select the place where is strong enough to withstand the full weight and...

Страница 19: ...nctions of magnetic tripping and heat tripping in order to protect the short circuit and overloading The min distance from the unit and combustive surface is 1 5m The outside static pressure is 0MPa w...

Страница 20: ...he ceiling Space to the wall Space to the wall Air outlet side Space to the obstruction Space to the wall Air intake side Air outlet side Space to the wall Above Above Above Above Above Above Above A...

Страница 21: ...placed at a downward slant Do not wrench or bend the drain pipe or flood its end by water 2 3 When the long drainage pipe passing through indoor wrap it with insulation materials Wrenched Bent Flooded...

Страница 22: ...tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and put them th rough the piping hole As show i...

Страница 23: ...hen connect the corresponding connector Ensure wire has been fixed well Power Install the Supply front side plate signal connetion wire connecting power cord Note cooling and heat pump type Wrong wiri...

Страница 24: ...or leakage detector to test if the outdoor unit and pipeline connection leak Air purging and leakage test Take out the nut cover of the inlet for refrigerant Align the center of the piping and tighten...

Страница 25: ...Has the unit been connected to a secure earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been...

Отзывы: