background image

Remote control

buttons of this control which are not available to this unit will not be described below.

This wireless remote control is universal, and it could be used for many units, some 

 Press this button, the Blow On and Blow

Off can be set up. Under the Cool and Dry

BLOW button

BLOW

turned on; When repressing this button 

once more, lcon 

Blow will be concealed,

at this time, the BLOW is turn off. After 

powered on, Blow Off is defaulted. If 

operating ON/OFF button and changing
mode to Cool, Dry, the status of BLOW 
will stay in the original position. If unit

is off, only Blow off can be set up and send 

the signal. This function is not available 
under the Auto, Fan and Heat mode 

and there is no Blow signal displayed.

 Under Cool or Heat mode, press this 

button can turn on or turn off the Turbo

TURBO button

TURBO

function.After the Turbo function turned 

on, the signal of Turbo will display. The

signal will be automatically cancelled if 
changing the mode or fan speed.

 Presetting temperature can be increased. 

Press this button, the temperature can be

+ button

+

set up, continuously press this button 

and hold for two seconds, the relative 

contents can quickly change, until unhold 

this button and send the order that the 

F)

signal will be displayed all the time. 

The temperature adjustment is unava-
ilable under the Auto mode, but the order 
can be sent if pressing this button. 
Temperature of Celsius degree setting:
16-30 ; for Fahrenheit degree setting: 
61-86. 

 Presetting temperature can be decreased. 

Press this button, the temperature can be 

- button

-

set up, continuously press this button 

and hold for two seconds, the relative 

contents can quickly change, until unhold 

this button and send the order that the 

F)

signal will be displayed all the time.  

The temperature adjustment is unav-
ailable under the Auto mode, but the order
can be sent by if pressing this button. 

Names and functions of wireless remote control

Operation of wireless remote control

mode, press this button once, the Icon 

Blow will be displayed, and BLOW is

QUIET DESIGN BUTTON

Press this button, the Quiet status is

under the Auto Quiet mode (display 

"Auto Quiet "signal ) and Quiet mode
(display "Quiet" singal)  and Quiet OFF
(there is no signal of "Quiet" displayed),
after powered on, the Quiet OFF is
defaulted. Note: the Quiet function 
cannot be set up in Fan and Dry mode;

signal), the fan speed is not available.

Under the Quiet mode (Display "Quiet" 

One press this key to enter into 

TIMER OFF setup, in which case

the TIMER OFF icon will blink. 

The method of setting is the same 

TIMER OFF

as for TIMER ON.

TIMER OFF  BUTTON

Содержание GWCN09JANK1A1A

Страница 1: ...me socket It can cause an electric shock or fire Don t operate the air conditioner with wet hands It can cause an electric shock to pull out the power supply It can cause an electric shock or fire Whe...

Страница 2: ...onditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the air conditioning capacity or cause a malfun...

Страница 3: ...e horizontal air flow Louver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blo...

Страница 4: ...indoor heat exchanger temperature is decreased below 0 degree the indoor unit microcomputer will stop compressor and outdoor fan running to protect the unit Working principle and special functions for...

Страница 5: ...ehumidifying for a long time there will be dew dripping off near the air outlet Gentle Breeze In the following situation the indoor unit may blow gentle breeze and the guide louver rotate to a certain...

Страница 6: ...oor unit Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable Displayer Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Heating Cooling Slie...

Страница 7: ...button the unit will be turned on press it once more the unit will be turned off Sleep function will be canceled while unit off HEAT initial value is 28 Under other modes the initial value is 25 82 7...

Страница 8: ...button and send the order that the signal will be displayed all the time The temperature adjustment is unava ilable under the Auto mode but the order can be sent if pressing this button Temperature o...

Страница 9: ...en repress this button this function will be turned off Press this button to set swing angle which circularly changes as below OFF This remote controller is universal If it receives threes kinds of fo...

Страница 10: ...later the temperature will be decreased 1 after that the unit will keep on running under this temperature 2 When setting the initial temperature 24 2 7 after turned on Sleep function the temperature w...

Страница 11: ...til 8hours later temperature setting finished sleep curve setting finished at this time the remote control will resume the original timer display temperature 88 will display the corresponding temperat...

Страница 12: ...ortable About turbo function If start this function the unit will run at super high fan speed to cool or heat quickly so that the ambient temp approachs the preset temp as soon as possible About AUTO...

Страница 13: ...ler is under off status press mode button and blow button simultaneously in order to enter or cancel this new function If the unit is under defrost mode dual eight position on remote controller will d...

Страница 14: ...liquid damage the wireless remote control It should be placed where is 1m away from the TV set or stereo sound sets The operation should be in its receiving range If the remote control cannot operate...

Страница 15: ...splayer indicator light off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the...

Страница 16: ...r unit in order to avoid hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dus...

Страница 17: ...t the dealer 1 Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Страница 18: ...blem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is ru...

Страница 19: ...sert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged I...

Страница 20: ...ng in the room Air switch or protection switch often breaks Carelessy splash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and disconnect Afte...

Страница 21: ...s For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where strong heat sources vapors flammable gas or volatil...

Страница 22: ...wo color wire in air conditioner is earthing wire and cannot be used for other purpose It can not be cut off and be fixed by screw otherwise it would cause electric shock The earth resistance should a...

Страница 23: ...obstruction Space to the wall Air outlet side Space to the wall Air inlet side Above Above Above Above Above A cm 34 2 55 0 B cm 18K Installation dimension of outdoor units Applicable units Outdoor u...

Страница 24: ...thstand the weight of an adult of 60kg further more the weight should be evenly shared by each screw Install the piping hole 1 Drill a hole 55 inclined outwards after confirmation of piping hole s loc...

Страница 25: ...ping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As show in Fig 8 Hange the mounting slots of the indoor unit on the upper tabs of the rear...

Страница 26: ...and connection and fixing place on the lead wire Handle Power connection wire Signal control wire Power connection wire Cool only type Heat pump type blue black brown yellow green violet orange blue b...

Страница 27: ...um gauge Vacuum pump Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pum...

Страница 28: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Страница 29: ...ice Notices for installation Installation dimension diagram Install indoor unit Install outdoor unit Test operation and check after installation This symbol stands for the items should be forbidden Th...

Страница 30: ...pt Post code 519070 OWNER S MANUAL Thank you for choosing GREE air conditioner For correct operation please read this owner s manual carefully before operating the unit and keeps it carefully for cons...