background image

4

4

Pré

cau

tio

ns 

d'u

sag

e

AVE

RTI

SSE

MEN

T

•N

e p

as a

ctiv

er l

'ali

men

tat

ion

 éle

ctri

que

 av

ant

 d'a

voir

 te

rm

iné

 l'in

sta

llat

ion

.

•S

i le

 câ

ble

 d'

alim

ent

atio

n e

st e

ndo

mm

agé

, a

fin

 d'

élim

ine

r le

s ri

squ

es 

de 

tou

s ty

pes

, il 

doi

t ê

tre

 re

mpl

acé

 pa

r le

 fa

bric

ant

, p

ar u

n d

ist

rib

ute

ur

aut

oris

é o

u p

ar t

out

e p

ers

onn

e q

ual

ifié

e.

•L

a te

mpé

rat

ure

 du

 cir

cui

t fr

igo

rig

ène

 se

ra 

éle

vée

 - v

eille

z à

 ga

rde

r le

 

câb

le 

d'in

ter

con

nex

ion

 lo

in 

du 

tub

e e

n c

uivr

e.

•L

e c

lim

atis

eur

 do

it ê

tre

 in

sta

llé

 co

nfo

rm

ém

ent

 au

x rè

gle

men

tat

ion

nat

ion

ale

s d

e c

âbl

age

 él

ect

riq

ue.

•L

'in

sta

lla

tio

n d

oit 

être

 fa

ite

 co

nfo

rm

ém

ent

 au

x n

orm

es 

NEC

 et

 CE

C, 

et s

eul

em

ent

 pa

r u

n te

chn

icie

n c

erti

fié

.

•L

e c

lim

atis

eur

 es

t u

n a

ppa

rei

l é

lec

triq

ue 

de 

cla

sse

 1 

qui

 do

it ê

tre

 m

is 

à la

 te

rre

 ad

équ

ate

men

t à

 l'a

ide

 d'

un 

disp

osit

if s

péc

ial

isé

 et

 pa

r u

tec

hni

cie

n c

erti

fié

.  A

ssu

rez

-vo

us 

que

 l'a

ppa

rei

l e

st t

ouj

our

s c

orre

cte

-

men

t m

is 

à la

 te

rre

, a

utre

men

t il 

y a

 ris

que

 de

 su

rch

arg

e é

lec

triq

ue.

•L

e fi

l ja

une

-ve

rt d

u c

lim

atis

eur

 es

t le

 fil 

de 

mise

 à 

la 

ter

re 

et n

e p

eut

 

être

 ut

ilis

é p

our

 au

cun

e a

utre

 ap

plic

atio

n.

•L

a ré

sist

anc

e d

e la

 m

ise

 à 

la 

ter

re 

doi

t ré

pon

dre

 au

x n

orm

es 

de 

séc

urit

é n

atio

nal

e e

n m

atiè

re 

d'in

sta

lla

tio

ns 

éle

ctri

que

s.

•L

e ra

cco

rde

men

t d

e to

us 

les

 fils

 de

s u

nité

s in

tér

ieu

re 

et e

xté

rie

ure

 

doi

t ê

tre

 fa

it p

ar u

n te

chn

icie

n c

erti

fié

.

•S

i le

 câ

ble

 d'

alim

ent

atio

n n

'es

t p

as 

ass

ez 

lon

g, c

om

mun

iqu

ez 

ave

c le

fab

rica

nt o

u v

otre

 dé

tai

lla

nt a

uto

risé

 po

ur e

n o

bte

nir 

un 

aut

re 

de 

la 

bon

ne 

lon

gue

ur. 

 N'

ess

aye

z p

as 

de 

ral

lon

ger

 vo

us-

mêm

e le

 câ

ble

 

Precautions

WARNING

• Do not put through the power before finishing installation.

• If the power supply wire is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons in order 

to avoid a hazard.

• The temperature of refrigerant circuit will be high, please keep the 

interconnection cable away from the copper tube.

• The appliance shall be installed in accordance with national wiring 

regulations.

• Installation must be performed in accordance with the requirement of 

NEC and CEC by authorized personnel only.

• The air conditioner is a first class electric appliance. It must be 

properly grounded with specialized grounding device by a professio-

nal. Please make sure it is always grounded effectively, otherwise it 

may cause electric shock.

• The yellow-green wire in the the air conditioner is grounding wire, 

which can't be used for other purposes.

• The grounding resistance should comply with national electric safety 

regulations.

• All wires of indoor unit and outdoor unit should be connected by a 

professional.

• If the length of power connection wire is insufficient, please contact 

the supplier for a new one. Do not extend the wire yourself.

00762_BUILDER 15SEER 9K12K18K24K_Mise en page 1  16-06-02  14:48  Page8

Содержание GWC09MB-D3DNK Series

Страница 1: ...ase read this owner s manual carefully before operating the unit and keep it for future reference 00762_30 05 2016 Copyright GREE Canada 2016 GWC09MB D3DN K GWC12MB D3DN K GWC18MC D3DN K GWC24MD D3DN...

Страница 2: ......

Страница 3: ...34 Selection of installation location 34 Requirements for electric connection 35 Installation Installation of indoor unit 36 Installation of outdoor unit Vacuum pumping 41 Leakage detection 41 Check...

Страница 4: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Страница 5: ...ade by children Do not connect air conditioner to multi purpose socket Otherwise it may cause fire hazard Do disconnect power supply when cleaning air conditioner Otherwise it may cause electric shock...

Страница 6: ...control otherwise the remote control may no longer operate When below phenomenon occurs please turn off air conditioner and disconnect power immediately and then contact the dealer or qualified profes...

Страница 7: ...n switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring Air Conditioner should be properly grounded Incorrect grounding may cause electric shock Make sure...

Страница 8: ...nce with the requirement of NEC and CEC by authorized personnel only The air conditioner is a first class electric appliance It must be properly grounded with specialized grounding device by a profess...

Страница 9: ...s WARNING If you need to relocate the air conditioner to another place only a qualified person can perform the work Otherwise it may cause personal injury or damage Select a location which is out of r...

Страница 10: ...ator Temp indicator Cooling indicator Power indicator Receiver window Diplay Horizontal louver Indoor Unit NOTICE Actual product may be different from above graphics please refer to actual products Re...

Страница 11: ...4 6 2 5 7 ON OFF button 2 MODE button 3 button 4 FAN button 5 SWING button 6 SLEEP button 7 TIMER button Timer on Timer off Sending signal swing operation auto operation cool operation dry operation...

Страница 12: ...ure by 1 F C Hold or button for 2s set temperature on remote control will change quickly Release the button after your required set temperature is reached When setting Timer On or Timer Off press or b...

Страница 13: ...utton for 2s time will change quickly Release the button after your required set time is reached Then press TIMER button to confirm it T OFF and H icon will stop blinking When unit is off press this b...

Страница 14: ...ion for buttons on remote controller Function introduction for combination buttons Note Range of time setting is 0 5 24h The interval between two motions can t exceed 5s otherwise the remote controlle...

Страница 15: ...emove cover of battery box During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than...

Страница 16: ...clean the air conditioner Clean surface of indoor unit If the remote control is lost or damaged please use auxiliary button to turn on or turn off the air conditioner As shown in the figure open the p...

Страница 17: ...ry Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard 2 Clean filter Use a vacuum or water to clean the filter When the filter is very dirty use water below 45 c to cl...

Страница 18: ...overy 1 Many packing materials are recyclable Please dispose of them in appropriate recycling bin 2 If you want to get rid of the air conditioner please contact local dealer or recycling service cente...

Страница 19: ...been turned on which is normal After reaching set temperature indoor unit will stop blowing out air Eliminate obstacles Cut the power supply off and put the power back after about 3min and then turn...

Страница 20: ...temperature is in proper range Doors and windows are open Close doors and windows Adjust temperature to proper range Clean the filter Wait until the voltage resumes to normal Your required temperature...

Страница 21: ...d then turn on the unit again Outdoor unit emits vapor Heating mode is turned on During defrosting under heating mode it may produce vapor which is a normal Water flowing noise Has the air conditioner...

Страница 22: ...nusual sound during operation Air switch trips off frequently Air conditioner generates a burning smell Indoor unit is leaking ATTENTION Do not repair or refit the air conditioner by yourself If the a...

Страница 23: ...ll At least 15cm At least 15cm At least 250cm Space to the floor At least 300cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the obstruction Drainage pipe Space...

Страница 24: ...allation Installing the unit in the following places may cause malfunction If it is unavoidable please consult your local dealer or a certified technician 1 A place with strong heat sources vapors fla...

Страница 25: ...circuit will be high please keep the interconnection cable away from the copper tube 8 The appliance shall be installed in accordance with national wiring regulations 9 Installation must be performed...

Страница 26: ...ll with tapping screws ST4 2X25TA and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearby 1 Choose the p...

Страница 27: ...e plastic expansion particles are not provided and should be bought locally 1 The pipe can be led out in the direction of right rear right left or rear left 1 Aim the pipe joint at the corres ponding...

Страница 28: ...2 Bind the joint with tape 1 Open the panel remove the screw on the wiring cover and then take down the cover 30 40 4 open end wrench union nut pipe torque wrench indoor pipe outlet pipe drain hose ta...

Страница 29: ...the screw and then fix the power connection wire with wire clip After finishing wiring clamp the grounding wire yellow green wire into the wire crossing groove as shown in the following figure in ord...

Страница 30: ...all pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the...

Страница 31: ...protective measures when installing the outdoor unit Make sure the support can withstand at least four times the unit weight The outdoor unit should be installed at least 3cm above the floor in order...

Страница 32: ...to the wiring terminal according to the color fix themwith screws Note the wiring board is for reference only please refer to the actual one 3 Pretighten the union nut with hand 4 Tighten the union nu...

Страница 33: ...om in order to prevent rain from getting into the room The through wall height of drain hose shouldn t be higher than the outlet pipe hole of indoor unit The water outlet can t be placed in water in o...

Страница 34: ...remains in 0 1 MPa If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw c...

Страница 35: ...nsulation of pipeline sufficient Is water drained well Is the voltage of power supply according to the voltage marked on the nameplate Is electric wiring and pipeline installed correctly Is the unit g...

Страница 36: ...capacity Max length of connection pipe Max rise difference 25 10 30 10 30 20 28000Btu h 8204W 36000Btu h 10548W 30 20 42000Btu h 12306W 30 20 48000Btu h 14064W u 4 Additional regrigerant liquid and r...

Страница 37: ...r unit throttle Diameter of connection pipe Liquid pipe mm Cooling only g m Cooling and heating g m Gas pipe mm Additional refrigerant charging amount for R410A 6 15 20 9 52 or 12 12 30 120 19 or 22 2...

Страница 38: ...th expander F Inspection Check the quality of expanding port If there is any blemish expand the port again according to the steps above 6 6 35 1 4 Note A varies according to the diameter please refer...

Отзывы: