background image

HIGH-WALL DUCTLESS 

AIR CONDITIONING & 

HEATING SYSTEM

OWNER’S MANUAL

Models:
GWH09AB-A3DNA1B
GWH12AB-A3DNA1B
GWH12AB-D3DNA1B

GWH18AB-D3DNA1B
GWH24AB-D3DNA1B

Thank you for selecting GREE evo High Wall 
Ductless Air Conditioner and Heating System. 
Please read this manual carefully before operation 
and keep it for further reference.

For more information, please visit our website at  

www.greecooling.com.

Содержание GWC09AB-D3DNA2D

Страница 1: ...A3DNA1B GWH12AB D3DNA1B GWH18AB D3DNA1B GWH24AB D3DNA1B Thank you for selecting GREE evo High Wall Ductless Air Conditioner and Heating System Please read this manual carefully before operation and ke...

Страница 2: ...ch will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor person...

Страница 3: ...nd immediately contact a qualified service professional WARNING Keep combustible materials away from the unit WARNING Do not attempt to install relocate or repair the unit yourself Contact a qualified...

Страница 4: ...o not allow cold air to directly blow on any person for a prolonged time This can cause discomfort and worsen health problems NOTE Do not use the unit to chill drinks preserving food or drying clothes...

Страница 5: ...ses as the outdoor temperature decreases Your evo unit will heat down to 5 F 15 C During extreme cold outdoor temperatures you may need an additional heating source to supplement the EVO heating outpu...

Страница 6: ...tdoor unit Air in Discharge air Air in Discharge air Front panel Filter Swing louvers Refrigerate lines and control wires Condesate drainage pipe Remote control Remote receiver sensor IDENTIFYING MAJO...

Страница 7: ...n Press the button and clock icon will flash Within 5 seconds set the time by pressing or buttons to set hours and minutes Press button again to save time setting Note that this is the current time no...

Страница 8: ...e by pressing the button When the guide louver begins to swing up or down it turns off the SWING function and will appear as the louver position is readjusting TIMER ON button When TIMER function is a...

Страница 9: ...d more than 64 F 17 8 C the system will be idle and the fan will run to circulate and filter air In this mode the set room temperature will not be displayed on the remote AUTO mode is the default sett...

Страница 10: ...p to 25 ft 7 6 m as long as there are no obstructions 1 2 3 4 WIRELESS REMOTE CONTROL OPERATION Replacing Batteries If the wireless remote control unit is lost or damaged use THE MANUAL OVERRIDE SWITC...

Страница 11: ...could cause damage or unit failure Never use abrasive cleaners on indoor or outdoor unit Use only slightly damp clean soft cloth or very mild cleansers CLEANING AND CARING FOR YOUR UNIT Cleaning the...

Страница 12: ...es You hear a water flowing sound Cause It is normal for the air conditioning system to make water flowing or Gurgling sounds from refrigerant pressures equalizing when the compressor starts and stops...

Страница 13: ...remote control not working The batteries might be low change the batteries The remote control must be within 25 ft 7 6m with no obstructions of the indoor unit If remote control is lost or damaged an...

Страница 14: ...uld contact a Qualified Service Professional for assistance Moisture or condensation on the discharge air louvers or outlet vents Cause It is normal for air conditioning system to develop condensation...

Страница 15: ...ns to intake or outlet vents 4 The location must withstand full weight and vibration of unit and permit safe installation 5 Select a dry location away from direct sunlight and strong winds 6 Select lo...

Страница 16: ...floor Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side 15cm 6 in Above 15cm 6 in Above 15cm 6 in 118 in 300 cm 72 in 183 cm 11 in 30 cm Above 11 in 30 cm Ab...

Страница 17: ...condensate pipe should be installed at a slight downward angle 2 Do not pull or bend the condensate pipe No trap requirement 3 Wrapping the condensate hose in insulation is recommended Connecting Ind...

Страница 18: ...nd water pipe with tape and put them through the piping hole See Fig 3 3 Align the mounting slots of the indoor unit on the upper tabs of the rear panel and check that the connection is firm See Fig 4...

Страница 19: ...s If no leak is detected release nitrogen and evacuate system to below 500 microns 3 Connect the joint of the charging hose to the vacuum pump 4 Open the handle of the Lo manifold valve 5 Open the vac...

Страница 20: ...cal malfunction and damage the unit The unit is properly grounded Could cause electrical leakage Electrical cables are as specified Could cause electrical malfunction Air Inlet and outlet are not cove...

Страница 21: ...Outdoor Unit 63 633063 For 230V heat pump models For 230V cool only models For 115V cool only models For 115V heat pump models 63633065 63633084 63633083 CIRCUIT DIAGRAMS 21...

Страница 22: ...warranty is subject to all provisions conditions limitations and exclusions listed below Five 5 years on all functional Parts including compressor All parts including compressor are warranted for a p...

Страница 23: ...ires lightning accidents corrosive environments rust etc or other conditions beyond the control of the Company 6 Parts not supplied or designated by Company or damages resulting from their use 7 Produ...

Страница 24: ...GREE 66162632 V2 0 GREE ELECTRIC APPLIANCES INC OF ZHUHAI www greecooling com...