Cassette Type Air Conditioner Unit
13
4.2.1 Outdoor unit dimension
D
A
B
C
E
Fig. 4.8
Table 4.3 Unit: mm
Item
Model
A
B
C
D
E
GUHN18NK3HO
955
395
700
560
360
GUHN24NK3HO
GUHN30NK3HO
980
425
790
610
395
GUHN36NM3HO
GUHN42NM3HO
1120
440
1100
631
400
GUHN48NM3HO
1120
440
1100
631
400
GUHN60NM3HO
980
410
1350
572
376
4.2.2 Condensate Drainage of the Outdoor Unit
Note: Only for the heat pump unit
(1).
It is required to install a drain pipe for the outdoor unit to drain out the condensate
water during heating operation. (only for the heat pump unit)
(2).
When installing the drain pipe, apart from the drain pipe mounting hole, all other
holes should be plugged so as to avoid water leakage. (only for the heat pump
unit)
(3).
Installation Method: Insert the pipe joint into the hole
φ
25 located at the base
plate of the unit and then connect the drain pipe to the pipe joint.