Multi Variable Air Conditioners Ducted Type Indoor Unit
2
0
9 Troubleshooting
The air conditioner is not expected to be serviced by users. Incorrect repair may cause
electric shock or fire, so please contact an authorized service center for professional service. The
following checks prior to contact may save your time and money.
Phenomenon
Troubleshooting
The unit can’t start
①
Power supply is not connected.
②
Circuit breaker tripping caused by leakage of electricity.
③
Input voltage is too low.
④
Defect of main PC-board.
The unit stops after running
for a while.
①
The inlet or outlet of ODU or IDU are blocked by obstacle.
Poor cooling
①
The filter is dirty.
②
Too heavy
a
heat load of room(e.g. too many
people in the room)
③
Door
s
or windows
are
open.
④
Inlet and outlet of IDU are blocked.
⑤
T
emperature is
set
too high.
⑥
Refrigerant is
low
(e.g. refrigerant leakage)
Poor heating
①
The filter is dirty.
②
Door
s
or window
s
are
open.
③
T
emperature
is
set t
oo low.
④
Refrigerant is
low
(e.g. refrigerant leakage)
Indoor fan doesn’t start
up during heating
①
At start
up
, the IDU fan
will
not operate
un
til the heat exchange
r (indoor coil)
become
s
hot,
to
prevent
cold air delivery.
②
In Defrost
, the IDU fan stop
s because the system temporarily switches to
the cooling mode, this prevents cold air deliverey
,
the fan will r
esume
operating after
defrosting.
NOTICE!
If
the
air conditioner still fails to work normally after checking and handling as described
above, please stop using it immediately and contact
a licensed HVAC technician
for assistance.