Multi Variable Air Conditioners Ducted Type Indoor Unit
16
3)
Shape the tail of wire into ring
using a
needle nose plier, and keep the gauge of
ring in
proportion to the
screw.
4)
Use
a
screwdriver for tightening the terminal.
(2) Connecting
stranded wire (as shown in fig 5.1.2)
1)
Strip about 10mm (3/8 in.) insulation of the end of stranded wire by stripping and cutting
tool.
2)
Loosen the screws on terminal board.
3)
Insert the wire into the ring tongue terminal and tighten by crimping tool.
4)
Use
a
screwdriver for tightening terminal
s
.
Unit: mm(in.)
Fig 5.1.1
Fig 5.1.2
5.2 Power Cord Connection
NOTICE!
①
Every unit should be equipped with a circuit breaker for short-circuit and overload
protection.
②
For the system to work properly
, all indoor units connected to the same outdoor unit
must be
kept energized
.
Fig 5.2.1
NOTICE!
Indoor unit quantity n is according to the outdoor unit capacity.
Outdoor unit connection
N(1) 2
3
black
red
green
white