Noise
Silencing
Protection
If the unit is stopped by pressing ON/OFF,
or mode switching,
the
reversal
valve will be stopped after 2-minute lag
.
Over
current
Protection
the same as that under cooling mode(
only indoor fan will run at low speed for 60 seconds before
it is stopped).
6.1.2.3.3 Defrosting Conditions and Process
When the condenser is detected to have frost, the system will enter into defrosting status, in which case the compressor
will continue to run,
the outdoor fan, 4-way valve and indoor fan will be stopped and the
heating
indicator will blink.
When it is detected that the frost in condenser is completely eliminated, the outdoor fan, 4-way valve and indoor fan will be
started , the compressor will keep running, and the
heating
indicator will stop blinking.
The first defrost after energization will last
10
minutes. Later, the defrost time can be adjusted according to the
quantity of frost. Defrost takes longer if more frost (Max. 12 minutes) and takes shorter if less frost (Min.
7.0
minutes).
The system will exit defrost mode upon completion of defrosting.
6.1.2.4 Fan mode
Under FAN mode, only the indoor fan runs at preset speed.
Under this mode,the temperature can be set within a range from 16 to 30 .
6.1.2.5 Auto Mode
Under this mode, the system will automatically select its run mode (cool, dehumidify, heat or fan) with the change of
ambient temperature.
When switch from auto heating mode to other mode, the reversal valve will be stopped after 2-minute lag.
For protection function, same as under cooling ,dehumidifying,fan and heating mode.There is 30s delay for mode switch.
6.1.3 Other Control
In this mode, according to
the change of
ambient temperature, indoor fan will select High,Middle and Low fan
speed auto
6.1.3.1 Automatic Control of Fan Speed
-
matically with an interval of changing at leasts
3mins and
30 s among the wind speeds
( first enter into Auto fan speed or
mode switch,there is no 3mins and 30 s delay).
6.1.3.2 Detection of Sensor Malfunction
In any mode(except defrosting), it will detect malfunctions of indoor sensors.If it detect that the room temp. sensor is short or
open circuit, the nixietube will display "F1"; if it detect that the tube temp. sensor is short or open circuit, the nixietube will
display "F2".
At "On" status, if above malfunction occurs, the indoor unit will be stopped at once and will display malfunction; at "Off" status
if above malfunction occurs, it don't display malfunction, if receving any remote controller signal, the unit will not act and will
6.1.3.3 Timer Function
6.1.3.3.1 AUTO ON
The system will continue to run if AUTO ON is set when the system is under ON status. If AUTO ON is set when the
system is under OFF status, the system will start to run under preset mode upon the time for auto start.
6.1.3.3.2 AUTO OFF
If
AUTO OFF
is set when the system is under OFF status, the system will maintain its standby status.
If AUTO OFF
is set when the system is under ON status, the system will be stopped upon the tIme for auto stop.
6.1.3.3.3 Time Change
When the timer is set, you can turn on/off the unit by remote control, and also can reset the time, the system will run
under the status preset lastly.
When the system is under ON status; set AUTO ON and AUTO OFF at the same time, the system will maintain its original
operating status till the time for AUTO OFF,and then will stop. When the system is under OFF status;set AUTO ON and
AUTO OFF at the same time, the system will maintain stop till the time for AUTO ON, and then will start to run. After that,
upon the time for AUTO ON everyday, the unit will start to run under preset mode and will stop upon the time for AUTO OFF.
If the time set for AUTO ON is the same as the time set for AUTO OFF;the system will accept AUTO OFF.
keep stop, here if receving "turn on" signal, it will display malfunction but will not start. After the compressor has stopped
for 3 mins and the malfunction has been eliminated, it will resume running.
6.1.3.4 Display
6.1.3.4.1 Display of Run Icon ,Dual 8 and Mode Icon
After de-energized and re-energized, all icons will display about 3 mins. When the unit is turned on and there is remote control
signal,it will display the preset temperature in dynamic for 10s and then will display the ambient temperature.When the unit
is turned on by the remote controller,Run Icon will light and the preset mode icon will be displayed at the same time. Under
the sleep mode or turn the light off, only the RUN Icon is bright(when the light is on, it can be turned off by press the swing
key twice continuously within 1s; when the light is off, it can be turned on by press the swing key twice continuously within 1s).
When the unit is switched off, all icons except the power indicator are black. There is a dual colour indicator on the running
display section, after energized, if the unit is standby, the run indicator will be red, and if the unit is running, the run indicator
will be green.
Содержание Bright Series
Страница 1: ...1 Introduction and Features Model Remarks Bright Series...
Страница 2: ...Model Remarks...
Страница 3: ...Model Remarks Bright Series...
Страница 4: ...Model Remarks...
Страница 18: ......
Страница 20: ...Air inlet grill Left Tube exit hole Top View U Rear View U wall plate Unit mm Right Tube exit hole...
Страница 21: ...Air inlet grill Left Tube exit hole Top View Ceiling Rear View Unit mm Right Tube exit hole Bright Series...
Страница 22: ...Air inlet grill Top View Ceiling Rear View Left Tube exit Sign Right Tube exit Sign...
Страница 24: ......
Страница 25: ...Wrench Nut Bolt Unit mm Over 600 Over 600 Over300 Over 600 Bright Series...
Страница 27: ...In case of any change in the Electrical Diagram shown above please follow the drawing on cabinet Bright Series...
Страница 28: ......
Страница 29: ...2 1 2 1 2 1 Bright Series...
Страница 58: ...8 Exploded View and Components and Parts List Exploded View of Components and Parts of Indoor Unit...
Страница 61: ...Exploded View of Components and Parts of Indoor Unit Bright Series...
Страница 64: ...Exploded View of Components and Parts of Indoor Unit...
Страница 66: ...Exploded View of Components and Parts of Indoor Unit...
Страница 68: ...Exploded View of Components and Parts of Outdoor Unit...
Страница 71: ...Exploded View of Components and Parts of Outdoor Unit Bright Series...
Страница 74: ...Exploded View of Components and Parts of Outdoor Unit...