6.3.3.11 Display
6.3.3.11.1 Display of Run Icon and Mode Icon
When turn on the unit,the Dual 8 nixietube will display preset temperature(range from 16 to 30 ).When PG motor locked
6.3.3.11.2 Display
protection occurs, the nixietube will display "H6".
Once eneygized, all icon will
flash in dynamic
.
When the unit is
turned on by remote controller, the RUN icon and the preset
Mode icon are bright at the same time. If the light key is turned off, only the RUN Icon is bright. When the unit is switched
off, all icons except the power indicator are black.
fan speed
Display of GWCN24B5NE1IB
Display of GWCN24B5NE1NB
GWCN18B5TD1LA; GWHN18B5TD1LA
6.3.3.12 Memory
remote control signal do not set timer function
, will memorize the
last remote control signal and run according to it. If the last
remote control signal has set timer function, the system is de-energized before the set time,when re-energized, the system
Memory contents: Mode, UP/DOWN Swing,
light,
Set temp, Set fan speed.
After de-energized, and re-energized, the unit will start to run with the memory function automatically.
The system, if the last
will memorize the timer function, the set time will recalculate. If the last remote control signal has set timer function and the
system is de-energized after the set time, when re-energized, the system will memorize the running status before de-energized.
1) When motor locked protection occurs, all loads stop (indoor fan, outer fan, compress etc, 4-way valve stop after 2 mins lag).
2) Once the motor locked protection occurs, it is need to power off the unit and then power on to resume to work.
3) When motor locked protection occurs, both the remote control receiving and pressing is available, but does not for specific
4) When motor locked protection occurs, if the unit is under "on" status, the malfunction indicator will display:if the unit is under
"H6" and the running indicator will blink.
control.
"off" status, the malfunction indicator will be turned off.The specific display method method: the dual 8 nixietube will display
Note: It will be treated as locked while the motor rotating speed is too low.
6.3.3.13 Indoor fan motor locked protection
Bright Series
Содержание Bright Series
Страница 1: ...1 Introduction and Features Model Remarks Bright Series...
Страница 2: ...Model Remarks...
Страница 3: ...Model Remarks Bright Series...
Страница 4: ...Model Remarks...
Страница 18: ......
Страница 20: ...Air inlet grill Left Tube exit hole Top View U Rear View U wall plate Unit mm Right Tube exit hole...
Страница 21: ...Air inlet grill Left Tube exit hole Top View Ceiling Rear View Unit mm Right Tube exit hole Bright Series...
Страница 22: ...Air inlet grill Top View Ceiling Rear View Left Tube exit Sign Right Tube exit Sign...
Страница 24: ......
Страница 25: ...Wrench Nut Bolt Unit mm Over 600 Over 600 Over300 Over 600 Bright Series...
Страница 27: ...In case of any change in the Electrical Diagram shown above please follow the drawing on cabinet Bright Series...
Страница 28: ......
Страница 29: ...2 1 2 1 2 1 Bright Series...
Страница 58: ...8 Exploded View and Components and Parts List Exploded View of Components and Parts of Indoor Unit...
Страница 61: ...Exploded View of Components and Parts of Indoor Unit Bright Series...
Страница 64: ...Exploded View of Components and Parts of Indoor Unit...
Страница 66: ...Exploded View of Components and Parts of Indoor Unit...
Страница 68: ...Exploded View of Components and Parts of Outdoor Unit...
Страница 71: ...Exploded View of Components and Parts of Outdoor Unit Bright Series...
Страница 74: ...Exploded View of Components and Parts of Outdoor Unit...