background image

Leclimatiseur

semet

enmarche

etarr

ê

tetrop

souventou

neclimatise

pasla

pi

è

ce.

Ŗ

Lafonction

d

'

économied

'

énergie(POWER

SAVER)

estactivée

(surcertains

mod

è

les

seulement).

UtilisezPOWER

SAVER

seulementquand

vousêtes

àl'extérieur

dufoyer

ou

quevous

dormez,puisque

leventilateur

necircule

pasl'air

dela

piècecontinuellement.

Utilisezles

fonctionsLOW

,HIGH

ouTURBO

pourun

confortoptimal.

Ŗ

Leclimatiseur

n

'

estpas

adé

q

uatpour

lagrandeur

devotre

pi

è

ce.

Vérifiezla

capacité

declimatisation

devotre

climatiseurde

pièce.Les

climatiseursde

piècesne

sontpas

construitspour

climatiserplusieurs

pièces.

Ŗ

Lefiltre

estsale

ouobstrué

pardes

débris.

Nettoyezle

filtreà

air.

Ŗ

Lesserpentins

del

'

évaporateurintérieur

etle

condenseurextérieur

sontsales

ouobstrués

pardes

débris.

Référez-vousà

"EntretienAnnuel".

Ŗ

Ily

aune

accumulationexcessive

dechaleur

oud

'

humiditédans

lapi

è

ce

(Cuissondans

uncontenant

sanscouvercle,

douche,etc.)

Utilisezun

ventilateurpour

évacuerla

chaleurou

l'humiditéde

lapièce.

Essayezde

nepas

utiliserd'appareils

produi-

santde

lachaleur

pendantle

momentle

pluschaud

dela

journée.

Ŗ

Lestrappes

d

'

aérationsont

obstruées.

Installezle

climatiseurà

unendroit

oùles

trappes

serontloin

d'obstructionstels

querideaux,

stores,meubles,

etc.

Ŗ

Latempérature

extérieureest

inférieure

à

Ň%Ň(

N'utilisezpas

votreclimatiseur

en

fonctionC

LIMATISA

TION

quandla

températureextérieure

estsous

la

barredes

1

Ň

C(6

0

Ň

F).

Ŗ

Latempérature

dela

pi

è

ce

q

uevous

tentezde

climatiserest

extr

ê

mementélevée.

Donnezplus

detemps

àvotre

climatiseurpour

réussirà

climatiserune

piècetrès

chaude.

Ŗ

Desfen

ê

tresou

portesdonnant

à

l

'

extérieursont

ouvertes.

Fermeztoutes

lesportes

et

fenêtres.

Ŗ

Lecontr

ô

led

'

évacuationd

'

air(sur

certainsmod

è

les)est

à

laposition

OUVERT(OPEN).

Glissezle

contrôleen

positionFERMÉ

(CLOSED)pour

uneclimatisation

maximale.

Ŗ

Selonle

mod

è

le,le

réglageTEMP/TIME

ouTEMPERA

TUREn

'

estpas

réglépour

une

températureassez

froide.

Ajustezle

contrôleTEMP/TIME

àun

réglageplus

froiden

appuyantsur

lebouton

(-)pour

réduirela

température,ou

ajustezle

contrôleT

EMPERATURE

àun

réglageplus

froiden

letournant

dansle

senscontraire

desaiguilles

d'unemontre.

Réglezla

vitessedu

ventilateur(F

ANSPEED)

auréglage

maximum:TURBO

ouHIGH

(ÉLEVÉ),selon

lemodèle.

Del

'

eaucoule

dubo

î

tier

à

l

'

intérieurde

notremaison

Ŗ

Leclimatiseur

n

'

estpas

aubon

niveau.

Leclimatiseur

devraitlégèrement

basculervers

lebas

àl'extérieur

.Mettez

leclimatiseur

àniveau

defaçon

àlui

donnercet

anglevers

l'ex-

térieurpour

assurerun

drainageadéquat.

Référez-vousà

"Instructionsd'Installation".

NOTE

:

Nepercez

jamaisde

trousdans

labase

demétal

nidans

leplateau

decollecte

d'eaude

condensationou

lagarantie

seranulle.

Air conditioner cycles on and off too much or does not cool

Ŗ

The Mode is set to Power Saver (on some models).

Use Power Saver only when you are

away from home or asleep, since the fan does not circulate the room air continuously. Use

Low, High or Turbo for your best comfort.

Ŗ

The air conditioner is not properly sized for your room.

Check the cooling capabilities of

your room air conditioner. Room air conditioners are not designed to cool multiple rooms.

Ŗ

The filter is dirty or obstructed by debris.

Clean the filter.

Ŗ

The inside evaporator and outside condenser coils are dirty or obstructed by debris.

See ”Annual maintenance.”

Ŗ

There is excessive heat or moisture (open container coo

k

ing, showers, etc.) in the

room.

Use a fan to exhaust heat or moisture from the room. Try not to use heat-producing

appliances during the hottest part of the day.

Ŗ

The louvers are bloc

k

ed.

Install the air conditioner in a location where the louvers are free

from curtains, blinds, furniture, etc.

Ŗ

The outside temperature is below

u(

(1

6

°C).

Do not try to operate your air conditioner

in the cooling mode when the outside temperature is below 60

°

F (16

°

C).

Ŗ

The temperature of the room you are trying to cool is extremely hot.

Allow extra time

for the air conditioner to cool off a very hot room.

Ŗ

Windows or doors to the outside are open.

Close all windows and doors.

Ŗ

The Exhaust control is set to OPEN (on some models).

Push the Exhaust control

CLOSED for maximum cooling.

Ŗ

Depending on model, the Temp/Time or Temperature control is not at a cool enough

setting.

Adjust the TEMP/TIME control to a cooler setting by pressing the minus button to

reduce the temperature or adjust the TEMPERATURE control to a cooler setting by turning

the knob clockwise. Set the FAN SPEED control to highest setting (Turbo or High, depen

ding on model).

Water drips from cabinet into your house

Ŗ

The air conditioner is not properly leveled.

The air conditioner should slope slightly

downward toward the outside.  Level the air conditioner to provide a downward slope toward

the outside to ensure proper drainage. See the Installation Instructions.

NOTE

:

Do not drill a whole in the bottom of the metal base and condensate pan.

16

16

Содержание 13-04594

Страница 1: ...our proof of purchase in a safe place for future reference Copyright Sunrise Tradex Corp 2011 CLI WWW GREE CA 1 866 680 GREE WWW GREE CA 1 866 680 GREE 13 04588 13 04590 13 04591 13 04592 13 04593 13 04594 13 04595 5 000 BTU 8 000 BTU 8 000 BTU 10 000 BTU 12 000 BTU 15 000 BTU 9 7 10 7 9 8 10 8 10 8 10 8 10 7 43 5476 13 04710 43 5485 15 000 BTU 10 7 MODEL N O COOLING CAPACITY EER BTU HR 6 400 BTU ...

Страница 2: ...ir Conditioner 6 Position the air conditioner 7 AIR CONDITIONER USE 9 About the controls on the air conditioner models with touch pads 9 Starting Your Air Conditioner Rotary Control 12 Changing Air Direction Cleaning the Front Panel TROUBLESHOOTING WARRANTY 13 Normal Sounds 13 AIR CONDITIONER CARE 14 Cleaning the Air Filter 14 14 Repairing Paint Damage 14 Annual Maintenance 14 15 ASSISTANCE OR SER...

Страница 3: ...n t immediately follow instructions You can be killed or seriously injured if you don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed DANGER WARNING IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or injury when using y...

Страница 4: ...llation parts are supplied for double hung windows Ŗ Adequate wall support for weight of air conditioner Air conditioner weighs 51 lb 23 kg to 65 lb 29 5 kg NOTES Ŗ Cabinet louvers must not be obstructed Air must be able to pass freely through the cabinet louvers Ŗ Your model may differ from the one shown The electrical ratings for your air conditioner are listed on the model and serial number lab...

Страница 5: ...n conformance with National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Power Supply Cord NOTE Your unit s device may differ from the one shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage c...

Страница 6: ...re for a standard double hung window You will need to modify them for other types of windows Ŗ The air conditioner can be installed without the accordion panels if needed to fit in a narrow window See the window opening dimensions Ŗ All supporting parts must be secured to firm wood masonry or metal Ŗ The electrical outlet must be within reach of the power cord Ŗ Follow the dimensions in the table ...

Страница 7: ...ame or the vinyl frame Attach securely with nails or screws provided by the installer 1 2 higher than storm window frame Wood Sill 1 2 higher than vinyl frame on some windows Vinyl frame Storm window frame Some models may have the seal strip already attached to the top mounting rail If applicable skip this step Remove the backing from the top mounting rail seal strip and attach the seal strip to t...

Страница 8: ...QP RCPGN G UWTG VQ WUG VJG RTQRGT RCPGN HQT GCEJ UKFG 6 RG 6 6 UETGYU 6QR NGHV 6QR TKIJV 6QR OQWPVKPI TCKN QVVQO OQWPVKPI TCKN 5NKFG VJG NGHV CPF TKIJV CEEQTFKQP RCPGNU KPVQ VJG VQR CPF DQVVQO OQWPVKPI TCKNU WV VJG YKPFQY UCUJ UGCN VQ VJG RTQRGT NGPIVJ 2GGN QHH VJG DCEMKPI CPF CVVCEJ VJG UGCN VQ VJG WPFGTUKFG QH VJG YKPFQY UCUJ 056 5 5 6 6 5722146 4 4 4 6 0 1 1 1 612 9 0 19 5 6 WV VJG HQCO VQR YKP...

Страница 9: ...pads Features and appearance will vary Lights next to the touch pads on the air conditioner control panel indicate the selected settings NOTE The display always shows the room temperature except when setting the temperature or the delay timer Controls Delay Timer Increase Decrease Pads Each touch of the Increase Decrease pads on the unit or the Increase Decrease pads on the remote control will set...

Страница 10: ...commande pour u délai si nécessaire ie appuyez sur la touche lay 1 24hr s éteigne obstacle pouvant trouve entre le mande iles sont récentes et ans la télécommande éteint est allumé alors qu il ode de Refroidissement our que le compresseur se mence à refroidir nt al S électionnez le mode ou High ture moyenne al Sélectionnez le ature plus basse silencieux ou durant la nuit églage à une température C...

Страница 11: ...de optimum comfort settings with the set temperature If the room needs more cooling the fan speed will automatically increase If the room needs less cooling the fan speed will automatically decrease NOTE Auto Fan Speed cannot be used when in the Fan Only Mode Auto Fan Speed Mode Fan Only venti Fonction de conserv Auto Fan Speed vite Mode Energy Saver Contrôle le ventilateur ON activé Le ventilateu...

Страница 12: ...male à maximal LOW COOL Pour Modèle Starting Your Air Conditioner Rotary Control Model 1 2 Select the fan speed See Fan Speed Set temperature See Temperature 15 Fan Speed Set FAN SPEED to the desired setting When the air conditioner is operating at Low Cool High Cool on some models Med Cool on some models the fan circulates air continuously High Cool on some models for normal to maximum cooling Lo...

Страница 13: ... use the wheel depending on model to direct the air right or left Rotate the whole cartridge to direct air up down or straight ahead Normal Sounds When your air conditioner is operating normally you may hear sounds such as Droplets of water hitting the condenser causing a pinging or clicking sound The water droplets help cool the condenser Air movement from the fan Clicks from the thermostat cycle...

Страница 14: ...r use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency 4 Replace air filter by sliding filter back into either side of unit Style 2 1 Turn off air conditioner 2 Remove air filter by pulling down on the indents in the top or sides of filter door and sliding air filter up and out Filter door is not removable 3 Use a vacuum cleaner to clean air filter If a...

Страница 15: ...ers Ŗ Too many appliances are being used on the same circuit Unplug or relocate appliances that share the same circuit Ŗ Time delay fuse or circuit breaker of the wrong capacity is being used Replace with a time delay fuse or circuit breaker of the correct capacity See Electrical Requirements Ŗ An extension cord is being used Do not use an extension cord with this or any other appliance Ŗ You are ...

Страница 16: ... heat producing appliances during the hottest part of the day Ŗ The louvers are blocked Install the air conditioner in a location where the louvers are free from curtains blinds furniture etc Ŗ The outside temperature is below u 16 C Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 60 F 16 C Ŗ The temperature of the room you are trying to cool is...

Страница 17: ... made with the same precision used to build every new appliance To locate factory authorized replacement parts in your area call us or your nearest designated service center IN CANADA Call the eXperience Center 1 866 680 GREE Our consultant provide assistance with Features and specifications on our full line of appliances Installation information Use and maintenance procedures Accessory and repair...

Страница 18: ...pering or failure to follow the operating and maintenance instructions provided in this owner s manual 4 Filter not duly authorized by GREE 6 Insurance and freight costs for the warranty service ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED TO A ONEYEAR 1 PERIOD COVERED BY THIS EXPRESS LIMITED WARRANTY GREE DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDEN...

Отзывы: