Installation Diagram
11
Valve Installation (External wastegate type)
(1) Install the 6ø Hose fitting onto "CN" and "COM" port on the
Valve unit.
(2) Install the Valve bracket using the supplied M4 Bolts. Then,
secure the Valve assembly to the body using the supplied
M6 Bolt and Rubber washer.
(3) Install a 6ø Hose fitting (sold separately) on the top of the
wastegate.
(4) Connect the 6ø Hose fitting that was just installed to the
"COM" port of the valve unit using the supplied 6ø Vacuum
hose.
(5) Connect the "NC" port to a good pressure source such as
the Compressor housing of a turbo using the supplied 6ø
Vacuum hose. (It is ok to tap into the same line that is going
to the bottom port on the wastegate)
Important!
• It is very important that the Rubber washer is used when
mounting the bracket to the body.
• Mount the Valve unit in a cool area where the unit will not get
hot or wet.
• It is normal for the Valve unit to make a clicking sound when
it is operating.
NC
COM
To Turbo compressor housing
or pressu source
Center unit
Controller
Display unit