Installation Diagram
Important!
• It is very important that the Rubber washer is used when
mounting the bracket to the body.
• Mount the Valve unit in a cool area where the unit will not get
hot or wet.
• Secure all the Vacuum connections with hose clamps.
• When routing the vacuum hoses, make sure not to kink or
twist the hoses.
• Make the hoses as short as possible.
• It is normal for the Valve unit to make a clicking sound when
it is operating.
10
Valve Installation (Actuator type)
COM
NO
To Turbo compressor housing
or pressure source
Actuator
(1) Remove all the plastic plugs from the Valve unit
(2) Install the 6ø Hose fitting on to "NO" and "COM" port on the
Valve unit.
(3) Install the Valve bracket using the supplied M4 bolts. Then,
secure the Valve assembly to the body using the supplied
M6 Bolt and Rubber washer.
(4) Disconnect the vacuum hose connecting the compressor
housing of the turbo to the actuator at the actuator side and
connect it to the "NO" side of the Valve unit.
(5) Connect the "COM" port to the actuator using the supplied
6ø vacuum hose.
e-01英語版 03.3.19 20:29 ページ 11
Содержание e-01
Страница 1: ...Instruction Manual e 01 03 3 19 20 28 1...