2018-07-24
401-312M
3PYP
Adjustments
68
Coulter Adjustments
The ideal operating depth for coulters is
1
/
4
inch (6 mm)
above opener depth. Although they may have originally
been set to this depth, coulter (and opener) blades wear
with time, and may need adjusting.
Adjusting the coulter depth is accomplished by
re-mounting the coulter blade in one of the six mounting
holes arranged in a staggered pattern in the coulter
bracket.
Refer to Figure 77 and Figure 78
Raise planter and install cylinder locks before working on
coulters. Row unit may be fully lowered or locked up. Do
not attempt to move blade when the current or new
position causes it to contact the ground during the
adjustment. Be careful around the front end of row units.
Row clear tines and coulter blades may be sharp.
To adjust coulter depth:
1.
Determine the present opener and coulter depths.
2.
Note which bracket hole the coulter is presently
using.
3.
Determine which new hole will position the coulter
closer to the
1
/
4
inch above depth. See the table
below. If none, don’t move it.
4.
Remove the
5
/
8
-11X4 inch bolt, lock washer and nut
( in
5.
Move the blade to the new position. Insert the bolt,
and tighten on the lock washer and nut.
6.
Re-adjust openers, if installed.
If a worn coulter cannot be adjusted to satisfactory
operating depth, replace coulter.
Hole
Number
Depth of (new) coulter blade relative to (new)
opener blades
2
1 inch (2.5 cm) above
3
1
/
2
inch (1.6 cm) above
5
1
/
4
inch (6.4 mm) above
1
0
4
3
/
8
inch (9.5 mm) below
6
3
/
4
inch (1.9 cm) below
Figure 77
25 Series Unit-Mounted Coulter
29124
7
Figure 78
Coulter Blade Mounting Holes
29125