NP2540
Appendix C - Accessory Installation
181
2019-04-12
417-459M
Add
NH
3
Divider Port
15. Wear PPE
a
. Verify that the system has been
discharged (see “
16. Locate the flow divider
for the left wing.
Verify that the pressure gauge
is reading zero.
17. Select one new:
830
-
406C AD 1/4MNPT X 3/8 HB SS
18. Choose any plug
on the divider. Position yourself
up-wind of the plug. Begin to slowly unscrew the
plug, watching for signs of pressure or residual
ammonia bleed-off. If any ammonia is detected, wait
for it to bleed off before continuing.
19. Replace the plug with the adapter
. Use pipe
sealant when installing a replacement port fitting.
Use only pipe sealant specified for use with
anhydrous ammonia, such as RectorSeal No. 5. Do
not use tape.
Cut New Tubing
Connect Side Dress Tubing
Refer to Figure 115 and Figure 114
20. Disconnect the delivery tubing at row 1, the
existing left-most row. Release any coiled-up length
from ties at the row. Make sure that there is enough
slack for a tube of this length to reach the side dress
row. If not, have your dealer contact the factory.
21. Release the remaining length of row 1 tubing all the
way back to the section divider
. Do not
disconnect it from the divider.
Measure the length of this tubing from divider
port
to row end cut. Re-route and reconnect it to
row 1. Do not re-tie until step 25.
22. Select one new:
990
-
259R EVA TUBING 3/8 ID
Cut this tubing to the length measured at step 21.
23. Select two new:
800
-
400C HOSE CLAMP NO.10 .593 ID SS
Slide one over each end of the new tubing.
24. Connect the new tubing
to the adapter
installed in step 19. Route the tubing along the rear
tool bar, passing through the pin axis at the wing
hinge. Coil up excess behind or around
b
the tool bar.
Connect the wing end to the coulter tine. Secure
both ends with clamps
.
25. Secure all tubing with ties provided.
26. Note change in swath for rate setting.
a. PPE: Personal Protective Equipment
b. Avoid tight bends and kinks if wrapping around the tool bar. Make coils nearly circular.
Figure 114
Install Side Dress Divider Port
34982
Suffocation, Blinding, Burning, Freezing, Disabling and
Disfigurement Hazards:
Do not perform this installation without PPE or without
verifying system discharge. This installation requires opening
a flow divider port to the atmosphere. This system segment
could contain liquid anhydrous ammonia (
NH
3
). It would
and could be fatal.
1
Figure 115
Install Side Dress Tubing
34983
1