2019-04-12
417-459M
NP2540
Appendix C - Accessory Installation
178
Dismount Rear Vantage I Coulters
This applies only to kit 407-907A and three-coulter
configurations. For single-coulter configurations, skip to
15. Using a grease pencil, note the locations of any
coulters using offset shanks.
Possible Agricultural Chemical Hazard:
Wear chemical gloves while handling disconnected drop lines.
Hose may contain residual amounts of chemical fluids.
Consult SDS
a
for material most recently applied.
16. At each rear coulter pivot, disconnect the tubing
from the grease bank. Use a cable tie to secure all
but the left-most row’s grease bank tubing to a U-bolt
at the front coulter clamp.
17. If installed, disconnect any fertilizer drop lines
at
rear coulters. Disconnect at the push-pull fitting.
18. Replace nozzles
or
with caps at each
disconnected nozzle, except the left-most nozzle.
19. At the left-most nozzle, adapt it for half rate:
If using orifice plates, replace the existing plate
with a smaller size, having a port area of
1
/
2
, or
slightly larger than
1
/
2
of the port area of the existing
plate. See page 98 for a table of plates and ports.
a. Safety Data Sheet
Figure 108
Drop Line and Grease Connections
36830
L41
L41
Figure 109
Fertilizer Nozzle Parts
34976
L38
L39
L40
L41
L39
L40
L38