Charge Mode
Discharge Mode
CH1
CH2
00 NiCd Auto Mode
NONE
AUTO
00:00:00
Start Verz. Zeit
Battery Check!!
Checking Battery...
0
After the expiration of the aforementioned 5 seconds within which you should
have at least made the choice of a particular discharge mode as well as the
input of a delayed start, it starts an automatic battery test.
If no battery is connected, or an improper battery is detected, after completion
of the battery test it will be shown an appropriate error message, see „Alert
messages“ on page 48.
PM
01:24:12
DISCHG
Charge Mode
Discharge Mode
CH1
CH2
13 LiPo 03s 2200
NONE
NORMAL
00:00:00
Start Verz. Zeit
Connected Check
[ 3 ] cells are now con-
nected at the balancing
port.
5
NiCd and NiMH batteries charge process starts as described below by way of
example for a lithium battery after about 5 seconds. For lithium batteries and
PB after few seconds the battery test, it is carried out a review of the number
of cells connected batteries.
For lithium batteries and PB after few seconds the battery test, it is
carried out a review of the number of cells connected batteries. Is the
battery to charge connected not only with the charger, but also with a
balancer to the charger, the cell count is determined by the balancer and the
outcome of the review appears as shown on the left example.
PM
01:24:12
DISCHG
Charge Mode
Discharge Mode
CH1
CH2
13 LiPo 03s 2200
NONE
NORMAL
00:00:00
Start Verz. Zeit
Select Cells
5
Select[ 3 ] cells to be
charged or discharged
For lithium batteries and PB after few seconds the battery test, it is
carried out a review of the number of cells connected batteries.
Is the battery to charge connected without a balancer to the charger,
the cell count is based on the settings manually input and the outcome of the
review appears as shown on the left example.
If the displayed number of cells matches the actual number of cells of the con-
nected battery, wait until after about 5 seconds - as described below - charge
will start automatically.
PM
01:24:12
DISCHG
Charge Mode
Discharge Mode
CH1
CH2
13 LiPo 03s 2200
NONE
NORMAL
00:00:00
Start Verz. Zeit
Verbindungs Check
5
Select [ 4 ] cells to be
charged or discharged
** Check Cells **
If the displayed number of cells, however, is NOT matching the actual
number of cells of the battery connected, then stop the automatic
timing by pressing the INC or DEC key and then adjust the number of
cells with one of these buttons accordingly. As an indication of the manual
intervention the color of the header information when prompted changes be-
tween red and blue.
!
ATTENTION!
As a result of incorrectly set number of cells or even a value too
far from cell voltages due to the balancer port, battery can ex-
plode and / or burn!
Press the ENTER button on the bottom right to start the discharge process.