Eng
lish
22
23
PM
06:12:34
CHARGE
Charge Mode
Discharge Mode
CH1
CH2
13 LiPo 03s 2200
CC/CV
NONE
00:00:00
Start Verz. Zeit
Connect Check
[ 3 ] cells are now con-
nected at the
balancing port.
5
NiCd and NiMH batteries charging process starts as described below by way
of example for a lithium battery after about 5 seconds.
For lithium batteries and PB after few seconds the battery test, it is carried out
a review of the number of cells of the connected battery.
Is the battery to charge connected not only with the charger, but also
with a balancer to the charger, the cell count is determined by the
balancer and the outcome of the review, as shown on the left exam-
ple.
PM
06:12:34
CHARGE
Charge Mode
Discharge Mode
CH1
CH2
13 LiPo 03s 2200
CC/CV
NONE
00:00:00
Start Verz. Zeit
Select Cells
5
Select[ 3 ] cells to be
charged or discharged
If the lithium or PB battery to charge is connected only with the charg-
er cable to the charger, the detected cell count is based on the total
current battery voltage and the outcome of the review is shown on the
left image.
If the displayed number of cells matches the actual number of cells of the con-
nected battery, wait until after about 5 seconds - as described below - charge
will start automatically.
PM
06:12:34
CHARGE
Charge Mode
Discharge Mode
CH1
CH2
13 LiPo 03s 2200
CC/CV
NONE
00:00:00
Start Verz. Zeit
Zellenzahl auswählen
5
Select [ 4 ] cells to be
charged or discharged
** Check Cells **
Is the displayed number of cells, however, NOT matching the actual
number of cells of the connected battery, then stop the automatic
timing by pressing the INC or DEC button and adjust the number of
cells with one of these buttons accordingly. As an indication of the manual
intervention the color of the header information when prompted changes be-
tween red and blue.
!
ATTENTION!
As a result of incorrectly set number of cells or even a value too
far from cells voltage connected to the balancer port, battery
can explode and / or burn!
Press the ENTER button on the bottom right to start charging.
PM
06:14:44
CC/CV
CH1
CH2
13 LiPo 03s 2200
0.0
°C
00:01:56
67
mAh
11.678
V
2.20
A
11.97Vin
33.3m
Ω
STOP
11,789
Vc
0,067
Vr
After the lapse of the aforementioned 5 seconds or if necessary, after a manu-
al start, charge process is begun. Otherwise, an error message is shown.
Note:
Tap the image to go directly to the „data display“, see page 35.