![GRAUPNER GR-12L HoTT Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/graupner/gr-12l-hott/gr-12l-hott_quick-start-manual_2258266007.webp)
RECEIVER 0.01 >
>ALARM VOLT: 3.7V
ALARM TEMP: 65`C
PERIOD: 10ms
SENSOR at CH5: No
SUMD at CH6: No
• ALARM VOLT:
Low voltage warning
If the receiver voltage drops below the set voltage, the transmitter or the telemetry
box beeps per second. Voltage range 3.5 ~ 5.6 V
• ALARM TEMP:
Temperatur warning
If the receiver temperature rises above the set temperature, the transmitter or the
telemetry box beeps per second. Temperature range 30 ~ 80 ° C
• PERIOD:
Cycle time
The PPM-cycle output of the receiver can be set to 10 ms and 20 ms. If only digital
servos are used, we recommend a cycle time of 10 ms, 20 ms in all other cases must
be set.
• SENSOR at CH5
„Yes“: channel is used as input for telemetry sensors.
„NO“: PPM channel is used as output.
• SUMD at CH6
„
Yes“: receiver is channel data as SUMD format.
„NO“: PPM signal channel outputs.
4. RX FREE MIXER
To arrive the Menü RX FREE MIXER just call „SETTINGS, VIEW“ from the telemtriemenü
and then press the „►“-button.
RX FREE MIXER <
>MIXER: 1
MASTER CH: 0
SLAVE CH: 0
TRIM: 0%
TRAVEL-: +100%
: +100%
If the mixer is already programmed into the transmitter mixer menus, you do not
use the „RX FREE MIXER“
ATTENTION!
3. Telemetrie-Setup
About SET, DISPLAY in the menu on the telemetry transmitter or the SMART BOX set-
tings for telemetry be called
Seite 3 Graupner S/J