![GRASS VALLEY KULA Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/grass-valley/kula/kula_installation-manual_2257938035.webp)
17
Kula
Installation Manual
IP
Mainframe Connections
QSFP Input/Outputs
2x 50GbE
A1/B1
are the Primary QSFP connections of the Upper 'A' and Lower ‘B’ card.
Inputs A1/B1
-
18x on each Primary 50GbE Input = 36x Primary Inputs Total -
SMPTE 2022-6
or VSF TR-03 (SMPTE 2110) SD/HD/1080p inputs across two 50GbE links. Each 50GbE link
transports 9x SMPTE 2022-6 or VSF TR-03 (SMPTE 2110) SD/HD/1080p inputs.
Outputs A1/B1
-
6x on each Primary 50GbE Output = 12x Primary Outputs Total
- SMPTE
2022-6 or VSF TR-03 (SMPTE 2110) SD/HD/1080p outputs across two 50GbE links. Each 50GbE
link transports 3x SMPTE 2022-6 or VSF TR-03 (SMPTE 2110) SD/HD/1080p outputs.
2x 50GbE
A2/B2
are the Secondary QSFP Input and Output connections for the Upper 'A' and
Lower ‘B’ card, giving redundancy.
Input BNCs
4 x HD/SD/1080p (270Mbps / 1.485Gbps / 2.97Gbps) Inputs.
Serial digital interface As REC601/ SMPTE/292M / SMPTE424M via BNC connectors.
Including 1 x 12G-SDI ( SMPTE 2082) single link BNC connectors (silver BNC).
Bi-directional Input/Output BNCs
These are bi-directional SD/HD and 1080p BNCs, used as Inputs or Outputs.
Содержание KULA
Страница 1: ...Installation Manual Issue 5 Rev 1 2020 10 29 KULA PRODUCTION SWITCHER ...
Страница 16: ...xvi Notices ...
Страница 20: ...2 Introduction About this Manual ...
Страница 40: ...22 Cabling and Connections Mainframe Connections ...
Страница 50: ...32 Environment and Location Ancillary Panels ...
Страница 61: ...43 Kula Installation Manual Desk Cutout Dimensions for K5P 1M E 19 Control Surface ...