3
Cabling and Connections
Kula KPX, KPP, K1X, K1P and K5P Control Surface Connectors
The Kula KPX, KPP (Program/Preview) Control Surface and the K5P 1M/E Control Surface
have Power, Network, Comms, Monitor Output connector (used to connect to a touch
screen monitor, used as the GUI) and a Network connection to the switcher mainframe. The
“Comms” ports on the KPX and KPP control surface are used as power and comms to the
Kula K1X and K1P control surfaces.
2x Comms Ports
Network Port to Mainframe
2x USB Connectors
2x External PSU
Connectors
1
2
3
4
5
Monitor Out
1
2
3
4
5
4x Comms Ports
6
6
1
2
3
4
5
Kula K5P (1M/E 19” Control Surface)
Kula KPP
Kula K1P
5
and
Kula KPX
and
Kula K1X
Note:
Only two of the Comms ports on the KPX and KPP control surface are
required to connect to the K1P control surface, they also provide power to
the K1X and K1P control surface, as these are “Comms” ports not Ethernet
ports. DO NOT connect any “Comms Ports” to an Ethernet Switch.
CAT5 or above cables - crossover cables are Not suitable.