64
KAM-SD-2AES-MUX Instruction Manual
KAM-SD-2AES-MUX Links and Web Pages
Frame Heath Reporting
The reporting of Slot Fault, Signal Loss, and Reference Loss can be enabled
or disabled to the Frame Health connector on the rear of the Kameleon
frame by selecting or deselecting the corresponding checkbox.
Hardware Switch Controls
This section is a read-only status report of 2000NET module switch settings
for Module Status Reporting and Asynchronous Status Reporting. These
functions must be enabled for the following Slot SNMP Trap Reports to
function.
Slot SNMP Trap Reports
This section is displayed only when the SNMP Agent software has been
installed on the 2000NET module (refer to the 2000NET Instruction Manual
for installation instructions). Slot SNMP traps can be enabled only when
the hardware switches for Module Fault reporting and Asynchronous
Status reporting are enabled on the 2000NET module (dipswitch S1
segment 7 and dipswitch S2 segment 1).
The enabled SNMP traps will be reported to any SNMP manager that is
identified as an SNMP Report Destination in 2000NET configuration. Trap
severity is read-only hard-coded information that is interpreted and
responded to by the SNMP Manager software configuration.