Environment and Location
Mainframe Location and Environment
Mainframe Location and Environment
Location Instructions
The Kahuna mainframes can be used freestanding (tabletop configuration) or installed in a
standard 483mm (19 inch) equipment rack. The following precautions should be observed:
1.
The cooling fan exhausts at the rear of the unit must not be obstructed - a minimum
clearance of 200mm (8 inches) is
ESSENTIAL
.
2.
Air intakes situated at the front, located at the top and bottom are to allow the inlet of
cooling air and
MUST NOT BE OBSTRUCTED.
The front door allows airflow through the
mainframe.
Kahuna 9600 11RU Mainframe Air Flow
The diagram above shows how cooling is provided by fans drawing air in at the front of the
mainframe and exhausting it at the rear. The mainframe should never be operated for any
significant period of time with the door open, as this will affect the internal air flow and cause
overheating.
Air flow through the
front of the mainframe
Mainframe Front
Mainframe Rear
Note:
Where Fins are not fitted to the mainframe rear; correct blanking
plates have to be fitted to ensure air-flow through the mainframe.