JUPITER CM-4400 Control Module Installation and Operating Manual
267
CM-4400 System Codes
4D
SerialTimeSync failed to set a serial
processor time reference
A synchronize time command is sent to each serial
processor.
If the processor fails to set its time, this event is
logged. The processor may also fail to load protocols
if the synchronize time command fails.
This indicates that the processor control channel is not
responding.
4E
One or more serial protocols did
not start correctly.
One or more of the configured serial protocols failed to
load on one or more of the connected serial proces-
sors.
This indicates a serial processor control channel fail-
ure or incorrect protocol module.
Probable cause is a protocol defined on the serial pro-
tocols tables is not a valid protocol for this CM-4400.
4F
Serial processor watchdog expired
on card %d.\nProcessor Restarted
The indicated serial processor failed to reset the hard-
ware watchdog timer indicating that a hang condition
existed on the processor.
The processor was reset by hardware and its program
will be restarted.
50
Error 0x %x scheduling actors for
the router control device.
An error occurred when trying to schedule actors to
the command scheduler.
System may be over loaded.
This is typically a critical problem. Contact Grass Val-
ley Technical support.
Table 20. Messages 51 to 58
Message Number
Short Message
Detailed Description
51
Configuration error for router con-
trol device %d.
An error occurred when trying to get the logical CP
number for this device.
The device was configured in the protocols table but
could not be found in the MPK devices table.
52
Error creating watch list for deferred
events.
When a time-deferred switch is created a watch list
observer is created so that the event handler will be
notified when the event runs.
Were not able to create the watch list observer. Possi-
bly too many observers are being used.
53
Failed to allocate memory
The system tried to allocate memory but failed.
This is always a fatal error. Contact Grass Valley Tech-
nical support.
54
Failed to free memory
The system tried to free memory but failed.
This is always a fatal error.
55
Can't open configuration file \"%s\"
(Error number 0x%X: %s)
There was a problem opening the configuration file.
56
Can't find configuration image
\"%s\" (\"%s\").
The configuration image was not found in the configu-
ration file.
The old configuration image will be used (or the
default if a valid one has not been loaded yet. Using
this old configuration image will typically give unde-
sirable results.
57
No Serial Ports defined.
No Serial Ports are defined in the configuration file.
This message is just for your information. Define
Serial ports if you are using serial control.
58
No Serial Protocols defined.
No Serial Protocols are defined in the configuration
file. This message is just for your information. Define a
Serial Protocol if you are using serial control.
Table 19. Messages 49 to 50
Message Number
Short Message
Detailed Description
Содержание JUPITER -
Страница 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Страница 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Страница 96: ...96 JUPITER CM 4400 Control Module Installation and Operating Manual Section 3 Software Installation ...
Страница 228: ...228 JUPITER CM 4400 Control Module Installation and Operating Manual Section 6 Jupiter Board Status ...
Страница 244: ...244 JUPITER CM 4400 Control Module Installation and Operating Manual Section 8 The Router Control Application ...
Страница 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...
Страница 276: ...276 JUPITER CM 4400 Control Module Installation and Operating Manual Section 12 Jupiter ASCII Communications Protocol ...
Страница 284: ...284 JUPITER CM 4400 Control Module Installation and Operating Manual Appendix A CM 4400 Specifications ...
Страница 306: ...306 JUPITER CM 4400 Control Module Installation and Operating Manual Appendix B Connecting Legacy and 3rd Party Routers ...
Страница 310: ...4 JUPITER CM 4400 Control Module Installation and Operating Manual Index ...