![GRASS VALLEY JUPITER - Скачать руководство пользователя страница 154](http://html.mh-extra.com/html/grass-valley/jupiter/jupiter_installation-and-operating-manual_2257589154.webp)
154
JUPITER CM-4400 Control Module Installation and Operating Manual
Section 5 — The Configurator Application
Additional Protocol Notes
ASC
(ASCII) refers to switcher control using Jupiter ASCII protocol com-
mands originating from an external computer (For example, an automation
system). When used with Diamond production switchers, the baud rate
must match the hardware setting on the DD production switcher XBAR
port (normally 38400). A technical description of the Jupiter ASCII com-
puter interface protocol is presented in
Jupiter ASCII Communications Pro-
tocol
on page 273
.
DTK
(Datatek D-2000/2166), HRZ (GVG Horizon), NXS (Nexus), and U96
(9600 baud connection to Utah UDI-1) all refer to CM-4400 boards control-
ling one or more of these “remote” (third party) routers. When selected, this
entry will apply to CM-4400odd-numbered ports only.
ESC
(ESbus control) is for controlling a “remote” (third-party) routing
switcher using the proposed ESbus routing switcher dialect.)
ESCP
(ES-Control Panel) is for a JEP-100 Jupiter / Control Panel operating
in Serial mode. For more information, refer to the JEP-100 manual, part no.
071 8376 xx.
ESW
(ESswitch) is a simplified version of the ESbus Tributary protocol.
This protocol allows a Grass Valley Crosspoint Bus router to be controlled
by an Encore control system, automation system, or third-party computer.
GNP
(Grass Valley Native Protocol) is used for Jupiter control of a Grass
Valley SMS 7000 or Encore control system (which is in turn connected to a
routing switcher).
TSL-UMD
(TSL) is for Television Systems Ltd. under monitor displays. For
more information, see Appendix S.
TRI
(Triton) routing switcher protocol.
Saturn Video Processor - Entry for MPK Port
The Saturn Master Control Switcher video processor (either digital or
analog) can be used as an alternate connection point for an MPK bus. (In
Saturn stand-alone systems, it would be the only MPK port available.)
Follow these steps to enter the MPK port:
1.
Select the MPK option from the drop-down list.
2.
Verify that “38400” has been entered in to the Baud 1/2-(CM 1) column.
All other ports can be left undefined.
An example entry is shown in Figure
Figure 110
.
Содержание JUPITER -
Страница 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Страница 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Страница 96: ...96 JUPITER CM 4400 Control Module Installation and Operating Manual Section 3 Software Installation ...
Страница 228: ...228 JUPITER CM 4400 Control Module Installation and Operating Manual Section 6 Jupiter Board Status ...
Страница 244: ...244 JUPITER CM 4400 Control Module Installation and Operating Manual Section 8 The Router Control Application ...
Страница 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...
Страница 276: ...276 JUPITER CM 4400 Control Module Installation and Operating Manual Section 12 Jupiter ASCII Communications Protocol ...
Страница 284: ...284 JUPITER CM 4400 Control Module Installation and Operating Manual Appendix A CM 4400 Specifications ...
Страница 306: ...306 JUPITER CM 4400 Control Module Installation and Operating Manual Appendix B Connecting Legacy and 3rd Party Routers ...
Страница 310: ...4 JUPITER CM 4400 Control Module Installation and Operating Manual Index ...