Property
Description
Enable
Loudness
Monitoring
Set to turn on the ALC input and output loudness monitoring for all programs.
Input
channels
selection
An input shuffler allows any combination of the available channels to be used as inputs to each
ALC program.
Note:
An input channel cannot be assigned to more than one program.
3.4.8.2 PGM1-4 tabs
According to the
Global Configuration
setting in the
Config
tab, these tabs set the ALC levels for the four programs.
Figure 28
GV ALC panel, PGM tab
Property
Description
Loudness
monitoring
When
Enable Loudness Monitoring
is set, the loudness meters display the program input
loudness before ALC processing (
Input (LKFS
/
LUFS)
), the dynamic correction applied by the
ALC (
Dynamic Regulation
), the ALC limiter correction (
ALC Regulation
), and the program
output loudness after ALC processing (
Output (LKFS
/
LUFS)
).
The input and output loudness are given in
LKFS
or
LUFS
, depending on the selected ALC filter
(LUFS for EBU R128 filtering, LKFS for the others). Loudness meters are integrated over a 10
second period using a “sliding-window”, which is equivalent to the
Short-term
mode i
n Dolby’s
LM100 loudness meter.
Dynamic and ALC regulation corrections are always given in dB. Each correction meter is
integrated over a period of 250 milliseconds.